Neurosurg Focus
-
OBJECTIVE The utilization of the Pipeline embolization device (PED) has increased significantly since its inception and original approval for use in large, broad-necked aneurysms of the internal carotid artery. While microsurgical clipping and advances in endovascular techniques have improved overall efficacy in achieving complete occlusion, recurrences still occur, and the best modality for retreatment remains controversial. Despite its efficacy in this setting, the role of PED utilization in the setting of recurrent aneurysms has not yet been well defined. ⋯ In the 2 cases in which PEDs were placed for treatment of residual aneurysms following prior flow diversion, 1 patient demonstrated asymptomatic vessel occlusion at 6 months, and the other exhibited complete aneurysm occlusion at 12 months. In patients with aneurysm recurrence following prior microsurgical clipping, the rate of complete occlusion was 100% at 6 and 12 months, with no adverse sequelae noted at a mean clinical follow-up of 27.7 months. CONCLUSIONS The treatment of recurrent aneurysms with the PED following previous endovascular coiling, flow diversion, or microsurgical clipping is associated with a high rate of complete occlusion and minimal morbidity.
-
OBJECTIVE Ruptured blister aneurysms remain challenging lesions for treatment due to their broad, shallow anatomy and thin, fragile wall. Historical challenges with both open microsurgical approaches and intrasaccular endovascular approaches have led to increased use of flow diversion for management of these aneurysms. However, the optimum paradigm, including timing of treatment, use of dual antiplatelet therapy, and number of flow-diverter devices to use remains unknown. ⋯ CONCLUSIONS Pipeline flow diversion is a technically feasible and effective treatment for ruptured blister aneurysms, particularly in good-grade patients without hydrocephalus. Patients with a worse grade on presentation and requiring EVDs may have higher risk for bleeding complications and poor outcome. There was no rebleeding from the target lesion with use of a single device in this series.
-
OBJECTIVE Flow diversion has emerged as a viable treatment option for selected intracranial aneurysms and recently has been gaining traction. The aim of this study was to evaluate the safety and effectiveness of flow-diverter devices (FDDs) over a long-term follow-up period. METHODS The authors retrospectively reviewed all cerebral aneurysm cases that had been admitted to the Division of Neurosurgery of the Università degli Studi di Napoli between November 2008 and November 2015 and treated with an FDD. ⋯ In the present study, the authors observed effective and stable aneurysm occlusion, even at the long-term follow-up. Data in this study also suggest that ischemic complications can occur at a later stage, particularly at 12-18 months. On the other hand, no other ischemic or hemorrhagic complications occurred beyond 24 months.
-
Case Reports
Novel use of flow diversion for the treatment of aneurysms associated with arteriovenous malformations.
The use of flow-diverting stents for intracranial aneurysms has become more prevalent, and flow diverters are now routinely used beyond their initial scope of approval at the proximal internal carotid artery. Although flow diversion for the treatment of cerebral aneurysms is becoming more commonplace, there have been no reports of its use to treat flow-related cerebral aneurysms associated with arteriovenous malformations (AVMs). The authors report the cases of 2 patients whose AVM-associated aneurysms were managed with flow diversion. ⋯ The patient underwent placement of a flow-diverting stent, and complete occlusion of the aneurysm was observed on a 7-month follow-up angiogram. These 2 cases illustrate the potential for use of flow diversion as a treatment strategy for feeding artery aneurysms associated with AVMs. Because of the need for dual antiplatelet medications after flow diversion in this patient population, however, this strategy should be used judiciously.
-
Objective The intelligent arm-support system, iArmS, which follows the surgeon's arm and automatically fixes it at an adequate position, was developed as an operation support robot. iArmS was designed to support the surgeon's forearm to prevent hand trembling and to alleviate fatigue during surgery with a microscope. In this study, the authors report on application of this robotic device to endoscopic endonasal transsphenoidal surgery (ETSS) and evaluate their initial experiences. Methods The study population consisted of 43 patients: 29 with pituitary adenoma, 3 with meningioma, 3 with Rathke's cleft cyst, 2 with craniopharyngioma, 2 with chordoma, and 4 with other conditions. ⋯ There were no complications related to use of the device. Conclusions The intelligent armrest, iArmS, seems to be safe and effective during ETSS. iArmS is helpful for improving the precision and safety not only for microscopic neurosurgery, but also for ETSS. Ongoing advances in robotics ensure the continued evolution of neurosurgery.