Eurosurveillance
-
Enterovirus D68 (EV-D68), phylogenetic clade B was identified in nasopharyngeal specimens of two cases of severe acute flaccid myelitis. The cases were six and five years-old and occurred in September and November 2014. EV-D68 is increasingly associated with acute flaccid myelitis in children, most cases being reported in the United States. Awareness of this possible neurological complication of enterovirus D68 infection is needed.
-
We report a case of laboratory-confirmed Zika virus infection imported into Europe from the Americas. The patient developed fever, rash, and oedema of hands and feet after returning to Italy from Brazil in late March 2015. The case highlights that, together with chikungunya virus and dengue virus, three major arboviruses are now co-circulating in Brazil. These arboviruses represent a burden for the healthcare systems in Brazil and other countries where competent mosquito vectors are present.
-
Increased febrile reactions in Australian children from one influenza vaccine brand in 2010 diminished confidence in influenza immunisation, highlighting the need for improved vaccine safety surveillance. AusVaxSafety, a national vaccine safety surveillance system collected adverse events in young children for 2015 influenza vaccine brands in real time through parent/carer reports via SMS/email. Weekly cumulative data on 3,340 children demonstrated low rates of fever (4.4%) and medical attendance (1.1%). Fever was more frequent with concomitant vaccination.
-
In the absence of a vaccine or specific treatments for Ebola virus disease (EVD), early identification of cases is crucial for the control of EVD epidemics. We evaluated a new extraction kit (SpeedXtract (SE), Qiagen) on sera and swabs in combination with an improved diagnostic reverse transcription recombinase polymerase amplification assay for the detection of Ebola virus (EBOV-RT-RPA). The performance of combined extraction and detection was best for swabs. ⋯ Of 928 post-mortem swabs, 120 tested positive, and the combined SE and EBOV-RT-RPA yielded a sensitivity and specificity of 100% in reference to one real-time RT-PCR assay. Another widely used real-time RT-PCR was much less sensitive than expected. Results were provided very fast within 30 to 60 min, and the field deployment of the mobile laboratory helped improve burial management and community engagement.
-
As part of the European Clostridium difficile infections (CDI) surveillance Network (ECDIS-Net), which aims to build capacity for CDI surveillance in Europe, we constructed a new network of hospital-based laboratories in Poland. We performed a survey in 13 randomly selected hospital-laboratories in different sites of the country to determine their annual CDI incidence rates from 2011 to 2013. Information on C. difficile laboratory diagnostic testing and indications for testing was also collected. ⋯ Of these, 159 were toxigenic and the majority belonged to two PCR-ribotypes: 027 (n=99; 62%) and the closely related ribotype 176 (n=22; 14%). The annual frequency of PCR-ribotype 027 was not significantly different during the surveillance periods (62.9% in 2012; 61.8% in 2013). Our results indicate that CDIs caused by PCR-ribotype 027 predominate in Polish hospitals participating in the surveillance, with the closely related 176 ribotype being the second most common agent of infection.