Journal of forensic sciences
-
Elevations in tryptase, a recently discovered mast cell enzyme, have been proposed as a postmortem indicator of fatal anaphylaxis. The previous studies had limited numbers of controls and thus the specificity of the test with postmortem samples was not known. Therefore, tryptase was evaluated in postmortem blood samples from 49 autopsy cases where there was no evidence of fatal anaphylaxis. ⋯ One autopsy specimen had a tryptase value of 106 ng/mL. The postmortem interval and the specimen storage condition did not appear to correlate with these elevations in tryptase. Although elevations in the postmortem tryptase remain an important supporting finding in the diagnosis of fatal anaphylaxis, it should not be used alone as the sole criterion for the postmortem diagnosis of anaphylaxis.
-
Comparative Study
Evaluation of the Abuscreen ONLINE assay for amphetamines on the Hitachi 737: comparison with EMIT and GC/MS methods.
The performance of the ONLINE Assay for Amphetamines on the Hitachi 737 was compared to the Syva Emit d.a.u. Assay and GC/MS. ⋯ The specificity was 99% (2937/2964) for ONLINE and 97% (2873/2964) for Emit. Agreement with GC/MS was 80% (110/137) for ONLINE and 55% (110/201) for Emit.
-
Case Reports
Terminal ballistics of the 9mm with Action Safety bullet or Blitz-Action-Trauma (BAT) ammunition.
Specialty ammunition creating atypical gunshot wounds of entrance can create confusion and may be misinterpreted by pathologists unfamiliar with the terminal ballistics of these projectiles. The previously unreported wound ballistics caused by the 9mm with Action Safety bullet described in a homicide highlights the atypical entrance wound(s) and wounding capacity of this novel ammunition. Manufactured by Geco division of Dynamit Nobel, the bullet consists of a nonjacketed solid copper alloy bullet body without a conventional lead core. ⋯ The radiolucent nose cap leaves the bullet's path but can still penetrate tissue giving the appearance of a separate but smaller entrance wound. The sharp leading edge of the deformation well and relative high velocity of the bullet body creates a punched out entrance wound with minimal marginal abrasion. When the plastic nose cap or fragments of the plastic post impact the subject, test firings may allow an inference to the muzzle-target distance even in the absence of soot deposition or stippling.
-
Case Reports
Disinterment from paving materials: use of heavy equipment for exhumation and examination of bodies.
Common paving materials--concrete and asphalt--pose an unusual and complex barrier to disinterment and examination of human remains. Although not commonly encountered, these materials are seen with sufficient frequency to justify consideration of the procedures and equipment necessary for disinterment. ⋯ In each of these cases, the material was slightly different in quality, and different tools--including heavy construction equipment--were necessary. Sometimes the paving material could be managed without heavy power tools, but occasionally specialized construction tools have proven very useful.
-
Firearm-related injuries are a leading cause of morbidity and mortality in the United States. Trauma care centers and trauma specialists (emergency medicine, trauma surgery, and neurosurgery) provide emergency care for those injured and mortally wounded from firearms. Consequently, trauma specialists may be asked to address forensic questions regarding gunshot wounds. ⋯ Twenty four (52.2%) were misinterpreted by trauma specialists. Errors included inaccurate determination of the total number of multiple penetrating and/or perforating gunshot wounds and erroneous identification of entrance and exit wounds. Of the exiting, single gunshot wounds 37% were misclassified and 73.6% of multiple gunshot wounds were interpreted incorrectly.(ABSTRACT TRUNCATED AT 250 WORDS)