Bullous skin diseases represent a group of organ-specific autoimmune disorders characterised by binding of circulating autoantibodies to adhesion molecules of the epidermis and the dermo-epidermal basement membrane zone. Binding of these autoantibodies to their antigenic targets results in loss of adhesion between epidermal keratinocytes and at the level of the basement membrane zone. Chronic blisters and secondary painful erosions are the clinical hallmark of autoimmune bullous disorders. ⋯ Tissue-bound autoantibodies are detected by direct immunofluorescence of perilesional skin. Circulating autoantibodies can be visualised by indirect immunofluorescence using tissue substrates such as monkey oesophagus and sodium chloride-split human skin. Most of the autoantigens are available as recombinant proteins, which allows for autoantibody screening by ELISA or immunoblot analysis to confirm the primary diagnosis and, importantly, for immunoserological follow-up of patients.
-
Comparative Study
Drug screening in urine by cloned enzyme donor immunoassay (CEDIA) and kinetic interaction of microparticles in solution (KIMS): a comparative study.
Two commercially available drug-screening assays were evaluated: the Roche kinetic interaction of microparticles in solution (KIMS) assay and the Microgenics cloned enzyme donor immunoassay (CEDIA). Urine samples from known drug-abuse patients were analyzed for amphetamines, barbiturates, benzodiazepines, benzoylecgonine, cannabinoids, LSD, methadone and opiates. Samples with discordant findings for the two assays were analyzed by gas chromatography/mass spectrometry (GC/MS) or gas chromatography/electron capture detection (GC/ECD). ⋯ Methadone showed 97.5% concordant results, with two false positives by CEDIA, and one false positive and one false negative by KIMS. Opiates showed 96.9% concordant results, with no false KIMS results, but four false positives by CEDIA. The results indicate that the agreement of the CEDIA and KIMS results for the eight drugs is rather good (93.3-100%).
-
The determination of cardiac troponins is routinely used for rule in/out, risk stratification, and follow-up of patients with acute coronary artery syndrome. We evaluated the analytical and clinical performance of the advanced immunoassay for troponin I (cTnI) carried out on an AxSYM platform (Abbott Diagnostic Division) and compared these characteristics to those of the previous version of this assay and to cTnI on the Access 2 immunoassay system (Beckman Coulter, Inc.). ⋯ The present study indicates that the AxSYM Troponin-I ADV immunoassay shows improved analytical sensitivity compared to the OLD AxSYM method, as well as very similar clinical results to those determined using the Access method.
-
Comparative Study
Influence of the needle bore size used for collecting venous blood samples on routine clinical chemistry testing.
Despite remarkable advances in technology and laboratory automation, results of laboratory testing still suffer from a high degree of preanalytical variability. Although there is no definitive evidence, the use of small-gauge needles for venipuncture is usually discouraged to reduce the chance of producing unsuitable specimens. ⋯ The results of our investigation indicate that 23 G needles, if handled correctly, will not introduce any statistically or clinically significant error to the measurement results compared to a 21 G needle. For the 25 G needle, we observed increased variability for potassium compared to a 23 G needle. Small-bore needles of 25 G or less cannot be universally recommended when collecting venous blood for clinical chemistry testing and should be reserved for selected circumstances, such as in patients with problematical venous accesses and newborns. In such cases, however, the bias introduced by the use of smaller needles should always be taken into consideration when interpreting test results.