The purpose of this study was to compare the effects of 0.5 fraction of inspired oxygen (FiO₂) and >0.95 FiO₂ on pulmonary gas exchange, shunt fraction and oxygen delivery (DO₂) in dorsally recumbent horses during inhalant anesthesia. The use of 0.5 FiO₂ has the potential to reduce absorption atelectasis (compared to maximal FiO₂) and augment alveolar oxygen (O₂) tensions (compared to ambient air) thereby improving gas exchange and DO₂. Our hypothesis was that 0.5 FiO₂ would reduce ventilation-perfusion mismatching and increase the fraction of pulmonary blood flow that is oxygenated, thus improving arterial oxygen content and DO₂. ⋯ Reducing FiO₂ did not change alveolar dead space ventilation or shunt fraction in dorsally recumbent, mechanically ventilated horses during 3 hr of isoflurane anesthesia. Reducing FiO₂ in dorsally recumbent isoflurane anesthetized horses does not improve oxygenation or oxygen delivery.