Ventilator-associated pneumonia (VAP) is an acquired infection related primarily to the consequences of prolonged endotracheal intubation. It is considered the most important infectious challenge in the critical care setting. Preventable complications of hospital care are considered an important source of wasted health-care costs believed to consume up to 47% of annual expenditures in the United States. ⋯ Also discussed is how this debate has impacted public policy, leading to the new paradigm of ventilator-associated events. The limited ability of artificial airways to prevent microaspiration and biofilm build-up, as well as non-modifiable conditions increasing the risk of VAP, is described in detail. In addition, the origins of the mistaken but widely embraced notion that zero VAP is a realistic achievement are examined.
-
Although lifesaving, mechanical ventilation can itself be responsible for damage to lung parenchyma. This ventilator-induced lung injury is especially observed in already injured lungs of patients with ARDS. New ventilatory approaches are needed to safely treat patients with ARDS, and recent studies have suggested the potential utility of open-lung strategies. ⋯ HFOV delivers very small tidal volumes, to prevent volutrauma, at a constant (relatively high) mean airway pressure, thus avoiding atelectrauma. Despite their theoretical benefits, the utility of APRV and HFOV remains unproven and controversial for the routine treatment of ARDS in adult patients. This review is focused on the theoretical and practical aspects of APRV and HFOV, provides an overview of the current evidence, and addresses their possible use in the treatment of ARDS.
-
Breathing exercises with positive expiratory pressure (PEP) are used to improve pulmonary function and airway clearance. Different PEP devices are available, but there have been no studies that describe the pressure generated by different resistors. The purpose of this study was to compare pressures generated from the proprietary resistor components of 4 commercial flow-dependent PEP valves with all other parameters kept constant. ⋯ Pressures generated by the different proprietary resistor components of 4 commercial PEP devices were not comparable, even though the diameter of the resistors is reported to be the same. The pressures generated were significantly different, particularly when using small-diameter resistors at a high flow. Therefore, the resistors may not be interchangeable. This is important information for clinicians, particularly when considering PEP for patients who do not tolerate higher pressures.
-
Optimization of factors affecting aerosol delivery during mechanical ventilation in the pediatric population is important. We hypothesized that increasing the tidal volume (V(T)), using a vibrating mesh nebulizer, and placing the nebulizer at the ventilator would increase lung dose/delivery efficiency. ⋯ Optimization of inhaled drug delivery during pediatric mechanical ventilation should include careful selection of the type of delivery device and its placement in the ventilator circuit. Increasing V(T) during nebulization did not increase lung dose/delivery efficiency.