Respiratory care
-
Review
The Use of Mechanical Insufflation-Exsufflation in Invasively Ventilated Critically Ill Adults.
Mechanical insufflation-exsufflation (MI-E) is traditionally used in the neuromuscular population. There is growing interest of MI-E use in invasively ventilated critically ill adults. We aimed to map current evidence on MI-E use in invasively ventilated critically ill adults. ⋯ Only 3 studies reported the occurrence of adverse events. From qualitative data, the main barrier to MI-E use in this subject group was lack of knowledge and skills. We concluded that there is little consistency in how MI-E is used and reported, and therefore, recommendations about best practices are not possible.
-
It remains unknown if pediatric patients failing initial noninvasive ventilation (NIV) experience worse clinical outcomes than those successfully treated with NIV or those primarily intubated. ⋯ We demonstrated that critically ill pediatric subjects unsuccessfully trialed on NIV did not experience increased ICU length of stay or fewer ventilator-free days when compared to those on invasive mechanical ventilation alone, including in the pediatric ARDS subgroup. Our findings are predicated on a median time to intubation of < 2 h in the NIV failure group and the provision of adequate monitoring while on NIV.
-
Observational Study
Variation in Use of High-Flow Nasal Cannula and Noninvasive Ventilation Among Patients With COVID-19.
The use of high-flow nasal cannula (HFNC) and noninvasive ventilation (NIV) for hypoxemic respiratory failure secondary to COVID-19 are recommended by critical-care guidelines; however, apprehension about viral particle aerosolization and patient self-inflicted lung injury may have limited use. We aimed to describe hospital variation in the use and clinical outcomes of HFNC and NIV for the management of COVID-19. ⋯ Hospital variation in the use of HFNC and NIV for acute respiratory failure secondary to COVID-19 was great but was not associated with intubation or mortality. The wide variation and relatively low use of HFNC/NIV observed within our study signaled that implementation of increased HFNC/NIV use in patients with COVID-19 will require changes to current care delivery practices. (ClinicalTrials.gov registration NCT04323787.).
-
Methacholine challenge testing (MCT) is a common bronchoprovocation technique used to assess airway hyper-responsiveness. We previously demonstrated that the addition of a viral filter to the nebulizer exhalation limb substantially reduced expelled particles during MCT. Our aim was to evaluate whether this modification affects the delivered dose of methacholine. ⋯ The addition of a viral filter to the nebulizer exhalation limb did not affect methacholine dose during bronchoprovocation testing. Routine use of a viral filter should be considered to improve pulmonary function technician safety and infection control measures during the ongoing COVID-19 pandemic.
-
Recent observational studies of nebulizers placed on the wet side of the humidifier suggest that, after some time, considerable condensation can form, which triggers an occlusion alarm. In the current study, an inline breath-enhanced jet nebulizer was tested and compared in vitro with a vibrating mesh nebulizer on the humidifier dry-inlet side of the ventilator circuit. ⋯ Aerosol delivery during continuous infusion and bolus delivery was comparable between the inline breath-enhanced jet nebulizer and the vibrating mesh nebulizer, and was determined by pump flow and initial ventilator settings. Further adjustments in ventilator settings did not significantly affect drug delivery. Expiratory losses predicted by the duty cycle were reduced with placement of the nebulizer near the ventilator outlet.