Nitric oxide (NO) is a biologically active molecule approved for the treatment of pulmonary hypertension in newborn patients. Commercially available NO delivery systems use pressurized cylinders as the source of NO and a sensor to control the concentrations of NO and nitrogen dioxide (NO2) delivered. Cylinder-based delivery systems are safe and widely used around the world, but they are bulky, expensive, and reliant on a robust supply chain. ⋯ The development of easy-to-use, safe, and portable NO delivery systems may enable the delivery of NO in the out-patient setting or at home. Furthermore, non-cylinder-based NO generators reduce the cost of NO production and storage and may therefore make NO delivery feasible in low-resource settings. Here we review commercially available systems that can generate and administer inhalable NO.
-
Until now, transfusion-related acute lung injury (TRALI) has been considered the leading cause of blood transfusion-related diseases and death. In addition, there is no clinically effective treatment plan for TRALI. The aim of this study was to systematically summarize the literature on risk factors for TRALI in critical patients. ⋯ The risk factors that were positively correlated with TRALI in this study included number of transfusions and units of fresh frozen plasma. Age, female sex, tobacco use, chronic alcohol abuse, positive fluid balance, shock before transfusion, ASA score, and mechanical ventilation may be potential risk factors for TRALI. Our results suggest that host-related risk factors may play a more important role in the occurrence and development of TRALI than risk factors related to blood transfusions.