Respiratory care
-
There are limited data on lactate stability in whole blood. The purpose of this study was to determine whole blood lactate stability at room temperature and in slushed ice conditions. ⋯ Considering that a change in whole blood lactate concentration of ≥ 0.4 mmol/L is unacceptable instrument peer-group variation as defined by the College of American Pathologists, ice is no longer needed to stabilize whole blood lactate specimens when the draw time to analyze time is < 45 min. Samples remain stable even at 90 min when left on ice.
-
Randomized Controlled Trial
Electronic Medical Record-Based Pager Notification Reduces Excess Oxygen Exposure in Mechanically Ventilated Subjects.
Liberal oxygenation during mechanical ventilation is harmful in critically ill patients and in certain subsets of patients, including those with stroke, acute myocardial infarction, and cardiac arrest. Surveillance through electronic medical records improves safety of mechanical ventilation in the ICU. To date, this practice has not been used for oxygen titration ([Formula: see text]) in adults. We hypothesize that a surveillance system based on the electronic medical record to alert respiratory therapists to titrate [Formula: see text] is feasible, safe, and efficacious. ⋯ Use of an electronic surveillance system to titrate [Formula: see text] was safe and feasible and showed preliminary efficacy in reducing hyperoxemia. Our study serves to justify larger randomized controlled trials for [Formula: see text] titration.
-
Randomized Controlled Trial
Closed-Loop Oxygen Control Using a Novel Nasal High-Flow Device: A Randomized Crossover Trial.
Oxygen administration is recommended for patients with hypoxemia to achieve a target [Formula: see text] range. Strategies to achieve this in clinical practice are suboptimal. We investigated automatic oxygen titration using a novel nasal high-flow device with closed-loop oxygen control. The objective of this proof-of-concept study was to determine whether closed-loop control was able to respond to desaturation and subsequent recovery in a controlled laboratory-based environment. ⋯ This study provides proof-of-concept evidence that the novel nasal high-flow device with closed-loop control can respond to changes in [Formula: see text] outside a target saturation range using a model of exercise-induced desaturation and subsequent recovery.
-
Limited adult data suggest that airway driving pressure might better reflect the potential risk for lung injury than tidal volume based on ideal body weight, and the parameter correlates with mortality in ARDS. There is a lack of data about the effect of driving pressure on mortality in pediatric ARDS. This study aimed to evaluate the effect of driving pressure on morbidity and mortality of children with acute hypoxemic respiratory failure. ⋯ Below a threshold of 15 cm H2O, ΔP was associated with significantly decreased morbidity in children with acute hypoxemic respiratory failure.
-
During the COVID-19 pandemic, a need for innovative, inexpensive, and simple ventilator devices for mass use has emerged. The Oxylator (CPR Medical Devices, Markham, Ontario, Canada) is an FDA-approved, fist-size, portable ventilation device developed for out-of-hospital emergency ventilation. It has not been tested in conditions of severe lung injury or with added PEEP. We aimed to assess the performance and reliability of the device in simulated and experimental conditions of severe lung injury, and to derive monitoring methods to allow the delivery of safe, individualized ventilation during situations of surge. ⋯ The Oxylator is a simple device that delivered stable ventilation with tidal volumes within a clinically acceptable range in bench and porcine lung models with low compliance. External monitoring of respiratory timing is advisable, allowing tidal volume estimation and recognition of changes in respiratory mechanics. The device can be an efficient, low-cost, and practical rescue solution for providing short-term ventilatory support as a temporary bridge, but it requires a caregiver at the bedside.