Respiratory care
-
The threshold of the lower limit of the normal range of lung function has been suggested to be more accurate than the 0.7 fixed ratio (FEV1/FVC < 0.7) for a diagnosis of COPD. We aimed to explore the health status and risk factors of patients overdiagnosed with COPD when using the lower limit of the normal range as a diagnostic reference. ⋯ The subjects with overdiagnosed COPD had a better health status and lung function than the subjects who were correctly diagnosed. Older age, heavier weight, and exposure to cooking oil fumes or a new-built or newly renovated home were factors associated with the overdiagnosis of COPD. These findings may help reduce overdiagnosis of COPD.
-
The N95 filtering facepiece respirator (FFR) is the most popular individual protective device to reduce exposure to particulate matter. However, concerns have been raised with regard to its use because it can increase respiratory resistance and dead space. Therefore, this study assessed the safety of N95 use in patients with COPD and air-flow limitation. ⋯ This study demonstrated that subjects with COPD who had modified Medical Research Council dyspnea scale scores ≥ 3 or FEV1 < 30% predicted wear N95s only with care.
-
Respiratory support of the critically ill neonate has steadily shifted from invasive to noninvasive forms of support. There have recently been a number of important advances in our understanding of the changes to neonatal resuscitation practices as they pertain to clinically important outcomes, mechanisms of gas exchange for high-flow nasal cannula, and best use of noninvasive ventilation and predicting response. ⋯ Recently, volume-targeted ventilation, high-frequency ventilation, and different methods of assessing weaning and extubation have been investigated. This review summarizes a number of important advances that have been made in the management of prematurity and neonatal respiratory distress syndrome.
-
Randomized Controlled Trial
High-Flow Nasal Cannula May Not Reduce the Re-Intubation Rate after Extubation in Respiratory Failure Compared With a Large-Volume Nebulization-Based Humidifier.
High-flow nasal cannula (HFNC) therapy may reduce the re-intubation rate compared with conventional oxygen therapy. However, HFNC has not been sufficiently compared with conventional oxygen therapy with a heated humidifier, even though heated humidification is beneficial for facilitating airway clearance. ⋯ Compared with a large-volume nebulization-based humidifier, HFNC may not reduce the re-intubation rate within 7 d. However, because of insufficient statistical power, further studies are needed to reach a conclusion.