Respiratory care
-
Significant concern exists regarding the respiratory health of military personnel deployed to Southwest Asia, given their exposures to numerous environmental hazards. Although the deployed military force is generally assumed to be fit, the pre-deployment respiratory health of these individuals is largely unknown. ⋯ Pre-deployment evaluation of military personnel identified numerous soldiers with active pulmonary symptoms and abnormal spirometry. When combined with questions regarding asthma history, wheezing and exercise intolerance, spirometry may identify individuals at risk for deployment-related respiratory complaints.
-
Heliox (helium-oxygen mixture) has been shown to reduce turbulence and improve aerosol delivery in a range of clinical settings. We questioned whether heliox as compared with oxygen via high-flow nasal cannula (HFNC) would affect aerosol delivery. We hypothesized that heliox would have a significant effect on aerosol delivery as compared with oxygen with both quiet and distressed breathing patterns. ⋯ With a distressed breathing pattern, aerosol delivery was greater at 30 and 50 L/min than with a quiet breathing pattern. Trends toward higher inhaled dose with heliox during HFNC were not significant.
-
Tubing systems are an essential component of the ventilation circuit, connecting the ventilator to the patient's airways. Coaxial tubing systems incorporate the inspiratory tube within the lumen of the expiratory one. We hypothesized that by design, these tubing systems increase resistance to air flow compared with conventional ones. ⋯ Our findings suggest that the use of coaxial tubing systems should be carefully considered with respect to their increased resistance.
-
ARDS is characterized by decreased functional residual capacity (FRC), heterogeneous lung injury, and severe hypoxemia. Tidal ventilation is preferentially distributed to ventilated alveoli. Aerosolized prostaglandin I2 exploits this pathophysiology by inducing local vasodilation, thereby increasing ventilation-perfusion matching and reducing hypoxemia. Therefore, aerosolized prostaglandin I2 efficacy may depend upon FRC. Both PaO2 /FIO2 and compliance of the respiratory system (CRS) are indirect signifiers of FRC and thus may partly determine the response to aerosolized prostaglandin I2. ⋯ Aerosolized prostaglandin I2 improves oxygenation in approximately 60% of ARDS cases. A favorable response was most strongly associated with baseline PaO2 /FIO2 and CRS.
-
Randomized Controlled Trial
Effects of an Airway Clearance Device on Inflammation, Bacteriology, and Mucus Transport in Bronchiectasis.
Bronchiectasis is characterized by abnormal and permanent dilation of the bronchi, caused by the perpetuation of inflammation and impairment of mucociliary clearance. Physiotherapy techniques can help to decrease the retention of respiratory secretions. The flutter valve combines high-frequency oscillation and positive expiratory pressure to facilitate the removal of secretions. We evaluated the effects of the flutter valve on sputum inflammation, microbiology, and transport of respiratory secretions in patients with bronchiectasis. ⋯ The use of a flutter valve for 30 min/d for at least 4 weeks is enough to change physical properties and improve mucus transport by coughing and can contribute to the reduction of the total number of inflammatory cells of the respiratory secretions of subjects with bronchiectasis. (ClinicalTrials.gov registration NCT01209546.).