Respiratory care
-
Comparative Study
A Comparison of Carbon Dioxide Elimination Measurements Between a Portable Indirect Calorimeter and Volumetric Capnography Monitor: An In Vitro Simulation.
Gas exchange measurements for carbon dioxide elimination (V̇CO2 ) and oxygen consumption (V̇O2 ) have been used to derive resting energy expenditure and guide energy prescription. Volumetric capnography is used in intensive care units and provides V̇CO2 measurements that could be used for titrating respiratory and nutritional support. We have recently suggested that measuring V̇CO2 may be sufficient to obtain a reasonable estimate of energy expenditure. However, data describing the accuracy of gas exchange measurement devices are limited. ⋯ Currently available portable gas exchange monitors demonstrated acceptable agreement with reference V̇O2 and V̇CO2 values in an in vitro simulation. The devices demonstrated good agreement with each other.
-
Observational Study
Association Between High-Flow Nasal Cannula and End-Expiratory Esophageal Pressures in Premature Infants.
High-flow nasal cannula (HFNC) is commonly being used to provide noninvasive respiratory support in newborn infants. Continuous distending pressure generated by these devices in preterm infants has not been elucidated. The aim of this work was to determine the association between HFNC flow in L/min and end-expiratory esophageal pressure in cm H2O in premature infants. ⋯ HFNC-associated end-expiratory esophageal pressure is measurable in premature infants. There is a significant association between flows and generated esophageal pressures. There is also variability in the amount of end-expiratory esophageal pressure generated. These observations should be kept in mind when using high HFNC flows in preterm infants.
-
This study was to evaluate the subclinical left-ventricular (LV) systolic dysfunction with 2-dimensional speckle-tracking echocardiography in subjects with obstructive sleep apnea (OSA) with normal left ventricular ejection fraction and without any confounding disease that can cause myocardial dysfunction. ⋯ Three-layer longitudinal and circumferential LV systolic functions in OSA subjects with normal left ventricular ejection fraction are deteriorated in the subclinical stage. Two-dimensional speckle-tracking echocardiography can be used as an effective method in the determination of subclinical myocardial dysfunction in subjects with OSA.
-
To our knowledge, there is no study on the level of telomerase in subjects with COPD during an exacerbation period. The objective of this work was to compare lipid peroxidation, telomerase, zinc (Zn), copper (Cu), and malondialdehyde levels in asymptomatic smokers and subjects with COPD exacerbation. ⋯ The reason why the subjects had a reduced Cu/Zn ratio and increased levels of telomerase, Cu, and Zn is likely to be oxidative stress, which can be defined as an increased exposure to oxidants and/or decreased antioxidant capacities It is obvious from this study that lung oxidant-antioxidant balance is abnormal in subjects with COPD exacerbation and also that the increased level of telomerase is associated with this imbalance.