BMC anesthesiology
-
In many countries relatives are asked to consent on behalf of ICU patients prior to inclusion in clinical trials. However, the attitudes to drug trials among relatives of unconscious ICU patients are largely unknown. ⋯ In general, relatives to unconscious ICU patients expressed positive attitudes to drug trials in the ICU and the inclusion of their relative in drug trials. Consent by next-of-kin and deferred consent was acceptable to the majority of relatives.
-
Tracheal tube and laryngeal mask cuff pressure during anaesthesia - mandatory monitoring is in need.
To prevent endothelium and nerve lesions, tracheal tube and laryngeal mask cuff pressure is to be maintained at a low level and yet be high enough to secure air sealing. ⋯ For maintenance of epithelia flow and nerve function and at the same time secure air sealing, this evaluation indicates that the cuff pressure needs to be checked as part of the procedures involved in induction of anaesthesia and eventually checked during surgery.
-
Potassium depletion is common in hospitalized patients and can cause serious complications such as cardiac arrhythmias. In the intensive care unit (ICU) the majority of patients require potassium suppletion. However, there are no data regarding the optimal control target in critically ill patients. After open-heart surgery, patients have a strongly increased risk of atrial fibrillation or atrial flutter (AFF). In a novel trial design, we examined if in these patients different potassium control-targets within the normal range may have different effects on the incidence of AFF. ⋯ The GRIP-COMPASS trial is the first controlled clinical trial to date that compares potassium targets. Other novel methodological elements of the study are that it is performed in ICU patients where both targets are within the normal range and that a computer-assisted potassium suppletion algorithm is used.
-
Early goal directed therapy improves survival in patients with septic shock. Central venous pressure (CVP) monitoring is essential to guide adequate resuscitation. Use of peripherally inserted central catheters (PICC) is increasing, but little data exists comparing a PICC to a conventional CVP catheter. We studied the accuracy of a novel PICC to transmit static and dynamic pressures in vitro. ⋯ In vitro, no static or dynamic pressure differences were found between the PICC and a conventional CVP catheter. Clinical studies are required to assess whether the novel PICC has bedside equivalence to conventional catheters when measuring central venous pressures.
-
We sought to evaluate agreement between a new and widely implemented method of temperature measurement in critical care, temporal artery thermometry and an established method of core temperature measurement, bladder thermometry as performed in clinical practice. ⋯ Temporal artery thermometry produces somewhat surprising disagreement with an established method of core temperature measurement and should not to be used in situations where body temperature needs to be measured with accuracy.