BMC anesthesiology
-
Observational Study
Preoperative anxiety and its association with patients' desire for support - an observational study in adults.
Preoperative anxiety is prevalent and has harmful effects on postoperative outcomes. However, to date, it is still unclear (i) to what extent patients perceive preoperative anxiety as emotionally distressful, (ii) whether patients would welcome support from anesthesiologists in coping with their anxiety, and (iii) whether anxiety scores are useful for everyday clinical practice to determine patients' need for support. ⋯ All patients undergoing surgery should be screened for preoperative anxiety and the resulting desire for support to be able to determine who would welcome support. Anxiety scoring tools do not seem to be useful to identify these patients. By helping patients experience less preoperative anxiety, anesthesiologists may not only reduce patients' emotional distress but also have a positive impact on postoperative outcome.
-
Randomized Controlled Trial Comparative Study
A pilot study comparing three bend angles for lighted stylet intubation.
For successful lighted stylet intubation, bending the lighted stylet with an appropriate angle is a prerequisite. The purpose of this study was to compare three different bend angles of 70, 80, and 90 degrees for lighted stylet intubation. ⋯ The bend angle of the lighted stylet affected the time required for tracheal intubation and POST in our study. 80 and 90 degrees as a bend angle seem to be acceptable for clinicians in regard to success rate of lighted stylet intubation. Considering the success rate of lighted stylet intubation and POST, the bend angle of 80 degrees might be better than 70 and 90 degrees.
-
Multicenter Study Comparative Study
Immediate intravenous epinephrine versus early intravenous epinephrine for in-hospital cardiopulmonary arrest.
Intravenous epinephrine has been a key treatment in cardiopulmonary arrest since the early 1960s. The ideal timing for the first dose of epinephrinee is uncertain. We aimed to investigate the association of immediate epinephrine administration (within 1-min of recognition of cardiac arrest) with return of spontaneous circulation (ROSC) up to 24-h. ⋯ Immediate administration of epinephrine in conjunction with high-quality CPR is associated with higher rates of ROSC.
-
Case Reports
Rupture of an epidural filter connector during bolus administration of local anesthetic: a case report.
Epidural catheters are routinely placed for many surgical procedures and to treat various pain conditions. Known complications arising from epidural catheter equipment malfunction include epidural pump failure, epidural catheter shearing, epidural catheter connector failure, epidural filter connector cracking, and loss-of-resistance syringe malfunction. Practitioners need to be aware of these potentially dangerous complications and take measures to mitigate the chances of causing significant patient harm. We report on the complete breakage of an epidural filter connector during epidural bolus administration of local anesthetic by hand with a syringe. ⋯ This incident placed the patient and surrounding healthcare providers at substantial risk for injury and infection from the fractured epidural filter connector becoming a projectile object and from the local anesthetic spray. The most plausible cause of this event was from a large amount of pressure being applied to the filter connector. This may have occurred by excessive force being applied by hand to the syringe, by the presence of a clogged filter, or by the catheter being kinked or blocked proximal to the filter. Being aware of this deleterious complication and potentially modifying existing epidural bolus techniques, such as using smaller syringes with less applied force and checking all epidural components vigilantly prior to and during bolus administration, can help anesthesia providers deliver the safest possible care to patients with epidural catheters.
-
Clinical Trial
Sufentanil EC50 for endotracheal intubation with aerosol inhalation of carbonated lidocaine by ultrasonic atomizer.
Nebulized lidocaine reduced stress response for endotracheal intubation. However, the impact of novel lidocaine aerosol inhalation for intubation by ultrasonic atomizer was unclear. Hence, we designed aerosol inhalation of lidocaine by ultrasonic atomizer, to seek whether the dosage of sufentanil for intubation could be less or not. ⋯ Aerosol inhalation of lidocaine by ultrasonic atomizer reduced the dosage of sufentanil for endotracheal intubation. Lidocaine inhalation by ultrasonic atomizer for airway anesthesia with minimal dosage of sufentanil could be recommended, particularly in patients who need more stable hemodynamic changes or spontaneous respiration.