BMC anesthesiology
-
Comparative Study Observational Study
Validation of noninvasive continuous arterial pressure measurement by ClearSight System™ during induction of anesthesia for cardiovascular surgery.
Since blood pressure tends to be unstable during induction of anesthesia in patients undergoing cardiovascular surgery, an artery catheter is often inserted before induction to continuously monitor arterial pressure during induction of anesthesia. ClearSight System™ enables noninvasive continuous measurement of beat-to-beat arterial pressure via a single finger cuff without pain using photoplethysmographic technology. If ClearSight System™ can replace intra-arterial pressure measurement, blood pressure could be easily and noninvasively assessed. However, the validity of ClearSight System™ during induction of anesthesia in patients undergoing cardiovascular surgery has not been evaluated. The aim of this study was to compare blood pressure measured by ClearSight System™ with intra-arterial pressure during induction of anesthesia for cardiovascular surgery. ⋯ Mean arterial pressure measured by ClearSight System™ could be considered as an alternative for mean radial arterial pressure during induction of anesthesia for elective cardiovascular surgery.
-
The management of Acute Respiratory Distress Syndrome (ARDS) secondary to the novel Coronavirus Disease 2019 (COVID-19) proves to be challenging and controversial. Multiple studies have suggested the likelihood of an atypical pathophysiology to explain the spectrum of pulmonary and systemic manifestations caused by the virus. ⋯ Data derived from the experience of multiple centers around the world have demonstrated that initial clinical efforts should be focused into avoid intubation and mechanical ventilation in hypoxemic COVID-19 patients. On the other hand, COVID-19 patients progressing or presenting into frank ARDS with typical decreased pulmonary compliance, represents another clinical enigma to many clinicians, since routine therapeutic interventions for ARDS are still a subject of debate.
-
Comparative Study
Effects of awake caudal anesthesia on mean arterial blood pressure in very low birthweight infants.
Intraoperative blood pressure is a relevant variable for postoperative outcome in infants undergoing surgical procedures. It is therefore important to know whether the type of anesthesia has an impact on intraoperative blood pressure management in very low birth weight infants. Here, we retrospectively analyzed intraoperative blood pressure in very low birthweight infants receiving either awake caudal anesthesia without sedation, or caudal block in combination with general anesthesia, both for open inguinal hernia repair. ⋯ The study indicates that the use of caudal block as stand alone procedure for inguinal hernia repair in very low birthweight infants might be advantageous in preventing critical blood pressure drops compared to a combination of caudal block with general anesthesia.
-
Randomized Controlled Trial
Effectiveness of wound infusion of 0.2% ropivacaine by patient control analgesia pump after minithoracotomy aortic valve replacement: a randomized, double-blind, placebo-controlled trial.
Local anesthetic wound infusion has become an invaluable technique in multimodal analgesia. The effectiveness of wound infusion of 0.2% ropivacaine delivered by patient controlled analgesia (PCA) pump has not been evaluated in minimally invasive cardiac surgery. We tested the hypothesis that 0.2% ropivacaine wound infusion by PCA pump reduces the cumulative dose of opioid needed in the first 48 h after minithoracothomy aortic valve replacement (AVR). ⋯ Wound infusion of local anesthetic by PCA pump significantly reduced opioid dose needed and improves pain control postoperatively. We have also shown that it is a feasible method of analgesia and it should be considered in the multimodal pain control strategy following minimally invasive cardiac surgery.
-
Randomized Controlled Trial
Lung ultrasound score to determine the effect of fraction inspired oxygen during alveolar recruitment on absorption atelectasis in laparoscopic surgery: a randomized controlled trial.
Although the intraoperative alveolar recruitment maneuver (RM) efficiently treats atelectasis, the effect of FIO2 on atelectasis during RM is uncertain. We hypothesized that a high FIO2 (1.0) during RM would lead to a higher degree of postoperative atelectasis without benefiting oxygenation when compared to low FIO2 (0.4). ⋯ The modified LUSS before capnoperitoneum and RM (P = 0.747) were similar in both groups. However, the postoperative modified LUSS was significantly lower in the low FIO2 group (median difference 5.0, 95% CI 3.0-7.0, P < 0.001). Postoperatively, substantial atelectasis was more common in the high-FIO2 group (relative risk 1.77, 95% CI 1.27-2.47, P < 0.001). Intra- and postoperative PaO2 to FIO2 were similar with no postoperative pulmonary complications. Atelectasis occurred more frequently when RM was performed with high than with low FIO2; oxygenation was not benefitted by a high-FIO2. CONCLUSIONS: In patients undergoing laparoscopic surgery in the Trendelenburg position, absorption atelectasis occurred more frequently with high rather than low FIO2. No oxygenation benefit was observed in the high-FIO2 group.