BMC anesthesiology
-
Placement of a percutaneous coronary sinus catheter (CSC) by an anesthesiologist for retrograde cardioplegia in minimally invasive cardiac surgery is relatively safe in experienced hands. However, the popularity of its placement remains limited to a small number of centers due to its perceived complexity and potential complications. ⋯ The success rate of the placement was 89.1 % in our academic center. On average, placing the CSC added approximately one additional hour to the APT. This time is not an accurate representation of true catheter placement time, as it included time for preparation of the CSC, TEE, and fluoroscopy. We experienced one documented complication (coronary sinus injury), which was immediately diagnosed by TEE and fluoroscopy in the operating room. No variables associated with prolongation of APT or CSC placement failure were identified.
-
Randomized Controlled Trial Comparative Study
Effect of bevel direction on the success rate of ultrasound-guided radial arterial catheterization.
This study assessed the effect of bevel direction on the success rate of ultrasound guided radial artery catheterization. ⋯ The bevel-down approach during ultrasound-guided radial artery catheterization exhibited a higher success with fewer complications compared to the bevel-up approach.
-
Comparative Study Observational Study
Intraventricular intracranial pressure monitoring improves the outcome of older adults with severe traumatic brain injury: an observational, prospective study.
Intracranial pressure (ICP) monitoring is widely used in the management of patients with severe traumatic brain injury (TBI). However, there is limited evidence about the efficacy of ICP monitoring in older subjects (aged ≥65 years). This study evaluated the effect of intraventricular ICP monitoring on the outcome of older adults suffering from a severe TBI. ⋯ Intraventricular ICP monitoring may have beneficial effects on the decreased in-hospital mortality and improved 6-month outcome of older patients with severe TBI. However, given that this was an observational study conducted in a single institution, further well-designed randomized control trials are needed to evaluate the effect of intraventricular ICP monitoring on the outcome of older severe TBI patients.
-
Observational Study
Perioperative evaluation of respiratory impedance using the forced oscillation technique: a prospective observational study.
Intravascular fluid shifts, mechanical ventilation and inhalational anesthetic drugs may contribute to intraoperative lung injury. This prospective observational study measured the changes in respiratory impedance resulting from inhalational anesthesia and mechanical ventilation in adults undergoing transurethral resection of bladder tumors. The components of respiratory impedance (resistance and reactance) were measured using the forced oscillation technique (FOT). ⋯ All components measured by FOT deteriorated significantly after a relatively short period of general anesthesia and mechanical ventilation. All components of resistance increased. Of the reactance components, X5 decreased and Fres and ALX increased. Pre- and postoperative respiratory reactance correlated with parameters measured by spirometry.
-
The insertion of suction devices through endotracheal tubes (ETTs) increases airway resistance and the subsequent suctioning may reduce airway pressures and facilitate atelectasis. The aim of this study was to investigate how airway pressures and tidal volumes change when different combinations of suction equipment and ETT sizes are used, and to what extent unfavorable effects can be ameliorated by choice of ventilator settings. ⋯ Negative model airway pressure was induced by suctioning through small-size ETTs. The most extreme pressure and volume changes were ameliorated when conventional ventilator settings were used, such as PCV mode with short inspiration time and a trigger function sensitive to flow changes.