BMC anesthesiology
-
Randomized Controlled Trial Comparative Study
The influence of the direction of J-tip on the placement of a subclavian catheter: real time ultrasound-guided cannulation versus landmark method, a randomized controlled trial.
It has been reported that the direction of the guidewire J-tip is associated with misplacement of a central venous catheter. We hypothesized that real-time ultrasound-guided infraclavicular subclavian venous cannulation would be less influenced by the direction of guidewire J-tip compared to landmark method. ⋯ The proper placement of guidewire was less influenced by the direction of the guidewire J-tip with ultrasound-guided subclavian venous cannulation than with the landmark approach.
-
Randomized Controlled Trial Comparative Study
A modified technique to improve the outcome of intubation with a left-sided double-lumen endobronchial tube.
The use of a video-assisted laryngoscope (VL) has been shown to reduce the time to achieve intubation with a double-lumen endobronchial tube (DLT). As the blade of the VL is curved differently to a standard laryngoscope, the DLT must be angled into a hockey stick shape to fit properly. We conducted a study to establish which direction of angulation was best to facilitate correct positioning of the DLT when using a VL. ⋯ When placing a left-sided DLT using a VL, angling the bronchial lumen to a hockey stick shape that conceals the tracheal lumen saves time and ameliorates the severity of post-intubation complications.
-
Comparative Study
Extubation force depends upon angle of force application and fixation technique: a study of 7 methods.
Endotracheal tubes are frequently used to establish alternate airways. Precise placement of the tubes must be maintained to prevent serious complications. Several methods for fixation of endotracheal tubes are available. Available methods vary widely in form and functionality. Due to the unpredictable and dynamic nature of circumstances surrounding intubation, thorough evaluation of tube restraints may help reduce airway accidents such as tube dislodgement and unplanned extubation. ⋯ Clinically, forces can be applied to endotracheal tubes from various directions. Efficacies of different fixation techniques are sensitive to the angle of force application. Standard deviations, which could be used as a measure of fixator reliability, also vary with angle of force application and method of tube restraint. Findings presented in this study may be used to advance clinical implementation of current methods as well as fixator device design in an effort to reduce the incidence of unplanned extubation.
-
Randomized Controlled Trial Comparative Study
Influence of the timing of administration of crystalloid on maternal hypotension during spinal anesthesia for cesarean delivery: preload versus coload.
Prophylactic fluid preloading before spinal anesthesia has been a routine procedure to prevent maternal hypotension during cesarean delivery. Unlike colloid, timing of infusion of crystalloid may be important because of its short stay in intravascular space. We hypothesized that crystalloid loading just after intrathecal injection compared to preload would be more effective in preventing maternal hypotension. ⋯ In case of using crystalloids for cesarean delivery, coload is more effective than preload for the prevention of maternal hypotension after spinal anesthesia.
-
Randomized Controlled Trial
Tissue oxygenation as a target for goal-directed therapy in high-risk surgery: a pilot study.
Tissue hypoperfusion occurs frequently during surgery and may contribute to postoperative organ dysfunction. There is a need for perioperative treatment protocols aiming at improving tissue oxygenation (StO2). We hypothesised that intra-operative optimisation of StO2 improves tissue perfusion and thus reduces postoperative complications. Furthermore, we evaluated the feasibility of the optimisation algorithm used. ⋯ No statistically significant difference in outcome was realized through intraoperative optimization of StO2 values in this pilot study. The protocol used may be considered feasible for clinical practice. Further research is obligatory to define both the optimal StO2 threshold and intervention to treat tissue hypoperfusion.