Indian journal of anaesthesia
-
The incidence of difficulty in tracheal intubation has been reported to range from 0.5 to 18% in patients undergoing surgery. We aimed to elucidate the role of upper lip bite test (ULBT) with other prevailing tests, hyomental/thyrosternal distances (HMD/TSD), and the mandible length (ML) and their possible correlation in predicting difficulty in intubation. After institutional approval and informed consent were obtained, 300 consecutive patients aged 20-60 years of ASA physical status I and II, scheduled for elective surgical procedures requiring tracheal intubation and meeting the inclusion criteria, were enrolled in this study. ⋯ An agreement between laryngoscopic grading and HMD and ML also existed (0.003 and <0.001, respectively), but was comparatively weaker. The high specificity, NPV, PPV and accuracy of ULBT as revealed in this study could be a good rationale for its application in the prediction of difficulty or easiness in intubation. ML > 9 cm and HMD > 3.5 cm were good predictors of negative difficult intubation.
-
The purpose of this article is to review the fundamental aspects of obesity, pregnancy and a combination of both. The scientific aim is to understand the physiological changes, pathological clinical presentations and application of technical skills and pharmacological knowledge on this unique clinical condition. The goal of this presentation is to define the difficult airway, highlight the main reasons for difficult or failed intubation and propose a practical approach to management Throughout the review, an important component is the necessity for team work between the anaesthesiologist and the obstetrician. Certain protocols are recommended to meet the anaesthetic challenges and finally concluding with "what is new?" in obstetric anaesthesia.
-
Elective postoperative ventilation in patients undergoing "on pump" open heart surgery has been a standard practice. Ultra fast-track extubation in the operating room is now an accepted technique for "off pump" coronary artery bypass grafting. We tried to incorporate these experiences in on pump open heart surgery and compare the haemodynamic and respiratory parameters in the immediate postoperative period, in patients on standard postoperative ventilation for 8-12 hours. ⋯ Extubation was possible in more than 88% of cases (n=32 out of 36 cases) in Group E and none required reintubation for respiratory insufficiency. Respiratory, haemodynamic parameters and postoperative complications were comparable in both the groups in the postoperative period. Therefore, we can safely conclude that immediate extubation in the operating room after on pump open heart surgery is an alternative acceptable method to avoid postoperative ventilation and its related complications in selected patients.
-
Since the invention of pulse oximetry by Takuo Aoyagi in the early 1970s, its use has expanded beyond the perioperative care into neonatal, paediatric and adult intensive care units (ICUs). Pulse oximetry is one of the most important advances in respiratory monitoring as its readings (SpO(2)) are used clinically as an indirect estimation of arterial oxygen saturation (SaO(2)). ⋯ Also, there are no reports and comparative data of the reliability and precision of pulse oximetry when readings from five different sensor locations (viz. finger, palm, toe, sole and ear) are analysed simultaneously. To fill these lacunae of knowledge, we undertook the present study in 50 infants and children with cyanotic heart disease in the immediate post-corrective stage.
-
Intensive care unit (ICU) monitors have alarm options to intimate the staff of critical incidents but these alarms needs to be adjusted in every patient. With this objective in mind, this study was done among resident doctors, with the aim of assessing the existing attitude among resident doctors towards ICU alarm settings. This study was conducted among residents working at ICU of a multispeciality centre, with the help of a printed questionnaire. ⋯ The initial response to an alarm among all the residents was to disable the alarm temporarily and try to look for a cause. 92% of PGs and 98% of SRs were aware of alarms priority and colour coding. 55% residents believed that the alarm occurred due to patient disturbance, 15% believed that alarm was due to technical problem with monitor/sensor and 30% thought it was truly related to patient's clinical status. 82% residents set the alarms by themselves, 10% believed that alarms should be adjusted by nurse, 4% believed the technical staff should take responsibility of setting alarm limits and 4% believed that alarm levels should be pre-adjusted by the manufacturer. We conclude that although alarms are an important, indispensable, and lifesaving feature, they can be a nuisance and can compromise quality and safety of care by frequent false positive alarms. We should be familiar of the alarm modes, check and reset the alarm settings at regular interval or after a change in clinical status of the patient.