Randomized Controlled Trial Comparative Study Clinical Trial[Application of the laryngeal mask for elective percutaneous dilatation tracheotomy].
Percutaneous dilatational tracheostomy is an increasingly accepted procedure for bed-side tracheostomy. The exact positioning of the endotracheal tube, the localization of the point for puncturing the trachea and damage to the endotracheal tube and the cuff as well as to the bronchoscope due to the puncturing process are technical problems which can endanger the course of the operation. In a prospective randomized study, we examined whether use of the laryngeal mask airway (LMA) is a real alternative to the endotracheal tube during tracheostomy. ⋯ An increase in PetCO2 and a decrease in minute ventilation volume were observed in both groups. Regarding technical complications, the LMA is a safe alternative to the endotracheal tube. The choice of method should depend on the basic disease and the patient's ventilation requirements at the time of tracheostomy, while there is still a call for safe instruments guaranteeing sufficient sealing of the respiratory tract during the dilatational tracheostomy and simultaneous avoidance of technical problems during puncturing of the trachea and widening of the point of puncturing.
-
Anaesthesiol Reanim · Jan 1998
Review[Measuring muscle relaxation with mivacurium in comparison with mechano- and electromyography].
Based on survey of the literature, methodological problems of electromyographic and mechanomyographic neuromuscular monitoring are presented. Often mechanomyography (MMG) is accompanied by mechanical problems during the registration of the contractions in the operating theatre. In contrast to mechanomyography the registration of electromyographic signals is easier whereas the processing of electromyographic signals is more difficult. ⋯ A comparison of the mechanomyographic values and the electromyographic values leads to the following results: the MMG showed a significantly shorter onset time (p < 0.0001) and a significantly deeper maximum neuromuscular block (p = 0.0004) than the EMG. There were also significant differences between mechanomyographically and electromyographically measured recovery values regarding T1(75) (p = 0.0007), T1(90) (p < 0.0001), TOF0.8 (p = 0.0386) and T1(25-75) (p < 0.0001). On average, an ED95 of mivacurium showed a significantly slower recovery in the mechanomyogram than in the electromyogram.
-
Since the beginning of this century, a few biopolymers have been used as basic materials for volume substitution. Aside from gelatin and dextran, modified starch (hydroxyethyl starch, HES) is currently the first-choice means. Due to special manufacturing processes, different hydroxyethyl starches are now available. ⋯ The molecular parameters of HES also influence other effects, such as cumulation in various organs and hemostasis. Critical reading of current HES literature shows that many questions still have to be answered. At the same time ways and means of optimizing differential volume substitution therapy and hemodilution therapy are emerging.
-
The laryngeal mask was developed by Brain in 1981 and described for the first time in 1983. It has been applied a few million times worldwide since 1988. One of the main complication is soreness of the throat. ⋯ Also after narcoses with the laryngeal mask, the average pain scores decreased quickly on the first and second postoperative days (5.1 +/- 9.0 and 0.2 +/- 1.4). There were no differences regarding sore throats between narcoses with the laryngeal mask or intubation on these two postoperative days. Using both anaesthesiological methods, sore throat was not related to duration of anaesthesia or the experience of the anaesthetist.
-
Anaesthesiol Reanim · Jan 1998
Historical Article[Bellows or bag? Testing 10 ventilators and some medical history comments].
We compared a new bellows ventilator (Kendall Cardiovent) with two other bellows (Dräger Resutator 63, Tagg Breathsaver) and seven bag or ball ventilators (Aerodyne Hope, Ambu Mark 3, Ambu Silicon, Dräger Resutator 2000, Laerdal Resu, Mercury CPR, Weinmann Combibag). Tidal volumes were measured with two Laerdal Recording Resusci Annies, one lying on the floor, one in a bed. Twelve participants performed mask ventilation with all ten devices on both manikins for two minutes, trying to achieve tidal volumes of between 0.8 and 1.21 as recommended by the AHA. ⋯ The Cardiovent provided exact ventilation with 95% of ventilations) on the floor and 78% of ventilations in bed in the recommended range. However, the percentage of correct ventilations with the Cardiovent was not significantly different to the other devices except for a lower percentage of correct ventilations with the Combibag in the in bed setting. Concerning subjective handling, the Cardiovent was significantly superior to several ball ventilators.