The American review of respiratory disease
-
Am. Rev. Respir. Dis. · Sep 1992
Case ReportsPulmonary edema associated with salt water near-drowning: new insights.
In this case report we describe the clinical and laboratory findings of a man who nearly drowned after aspirating a large quantity of seawater. The aspiration of salt water, which is strongly hypertonic with respect to plasma, resulted in severe pulmonary edema, both from the quantity of aspirated seawater and the osmotically driven ultrafiltrate of plasma that accumulated in the air spaces. ⋯ In addition, the magnesium concentration was markedly elevated because of the aspiration of magnesium-containing seawater, which may have diagnostic importance for near-drowning in salt water. The data from this case provide evidence for well-preserved alveolar epithelial barrier function after aspiration of large quantities of hypertonic salt water.
-
Am. Rev. Respir. Dis. · Aug 1992
Clinical Trial Controlled Clinical TrialAerosolized lidocaine reduces dose of topical anesthetic for bronchoscopy.
Conventional aerosol techniques were used to determine if inhalation of lidocaine can supplement topical anesthesia applied during bronchoscopy. Aerosols of either saline or lidocaine (50 mg at either 2 or 4% concentrations) were generated by jet nebulizer and administered with or without intermittent positive-pressure breathing. Patients (n = 38) after aerosol inhalation were administered 2% lidocaine (atomized and instilled) for suppression of the gag reflex, control of cough, and airway anesthesia. ⋯ Topical anesthetic dosage data were replicated in 12 additional patients studied by a different bronchoscopist. No additional benefit was afforded by premedication with 4% lidocaine aerosol rather than the 2% aerosol (n = 12). We conclude that aerosol modalities can supplement topical anesthesia during bronchoscopy, primarily by reducing the dose required to anesthetize the upper airway.
-
Am. Rev. Respir. Dis. · Aug 1992
Randomized Controlled Trial Comparative Study Clinical TrialEffect of inhaled furosemide and torasemide on bronchial response to ultrasonically nebulized distilled water in asthmatic subjects.
Inhaled furosemide has been shown to reduce the bronchoconstriction induced by several indirect stimuli, including ultrasonically nebulized distilled water (UNDW). Because the protective effect could be due to the inhibition of the Na(+)-2Cl(-)-K+ cotransport system of bronchial epithelium, we have compared the protective effect of inhaled furosemide with that of inhaled torasemide, a new and more potent loop diuretic, on UNDW-induced bronchoconstriction in a group of 12 asthmatic subjects. UNDW challenge was performed by constructing a stimulus-response curve with five increasing volume outputs of distilled water (from 0.5 to 5.2 ml/min) and the bronchial response expressed as the provocative output causing a 20% fall in FEV1 (PO20UNDW). ⋯ A remarkable increase in diuresis was noted only after torasemide in most subjects. We conclude that inhaled furosemide has a better protective effect than does inhaled torasemide against UNDW-induced bronchoconstriction. However, the protective effect of furosemide is variable, with some asthmatic patients showing no change in bronchial response to UNDW.(ABSTRACT TRUNCATED AT 250 WORDS)
-
Am. Rev. Respir. Dis. · Aug 1992
Delivery of a nebulized aerosol to a lung model during mechanical ventilation. Effect of ventilator settings and nebulizer type, position, and volume of fill.
Several factors may affect the delivery of a nebulized aerosol to the lung through an endotracheal tube during mechanical ventilation. To study these factors in vitro, a model representing ventilation of an adult patient was constructed by linking a Servo 900C ventilator to a standard humidified circuit and an endotracheal (ET) tube positioned within a pipe representing the trachea. This was connected via a filter to a lung simulator. ⋯ Under the same conditions, delivery was 3.1 and 4.4% using the Samsonic and Fisoneb ultrasonic nebulizers, respectively. Increasing the fill volume and the addition of an aerosol storage chamber increased delivery with all three nebulizers. These experiments suggest some simple ways of improving aerosol delivery during mechanical ventilation, including increasing the volume of nebulizer fill, repositioning the nebulizer in the ventilator circuit, adding an aerosol storage chamber, and adjusting ventilator settings to maximize delivery.
-
Am. Rev. Respir. Dis. · Aug 1992
Exposure-response relationships between occupational exposures and chronic respiratory illness: a community-based study.
Data from a random sample of 3,606 adults 40 to 69 yr of age residing in Beijing, China, were analyzed to investigate the association of reported occupational exposures to dusts and gases/fumes with the prevalence of chronic respiratory symptoms and level of pulmonary function. The prevalence of occupational dust exposure was 32%, and gas or fume exposure, 19%. After we adjusted for age, sex, area of residence, smoking status, coal stove heating, and education, an increased prevalence of chronic phlegm and breathlessness was significantly related to both types of exposures. ⋯ Among subjects who did not report using coal stove heating, dust exposure was a significant predictor for FEV1, FEV1/FVC, FEF25-75, and peak expiratory flow rate (PEFR). There was also a significant decrease for FEV1 and FVC with increase of gas/fume exposure levels. Both current and former smokers appeared to be more susceptible to the effect of dusts than the never smokers.(ABSTRACT TRUNCATED AT 250 WORDS)