Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery
-
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi · Oct 2015
[MINIMALLY INVASIVE SURGERY FOR DIRECT REPAIR OF LUMBAR SPONDYLOLYSIS BY UTILIZING INTRAOPERATIVE NAVIGATION AND MICROENDOSCOPIC TECHNIQUES].
To analyze the effectiveness of direct screw repair for lumbar spondylolysis by using intraoperative O-arm based navigation and microendoscopic techniques. ⋯ Debridement, autograft, and percutaneous intralaminar screw fixation by microendoscopy and O-arm based navigation may provide safe and effective treatment for spondylolysis. Minimally invasive direct repair can obtain satisfactory effectiveness.
-
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi · Oct 2015
[360 degrees INTERNAL FIXATION BY DOUBLE APPROACHES FOR HIGH-ENERGY CLOSED Pilon FRACTURES].
To observe the effectiveness of 360 degrees internal fixation by anteromedial and posterior-lateral approaches for high-energy closed Pilon fractures. ⋯ The effectiveness of the 360 degrees internal fixation for treatment of high-energy closed Pilon fractures has the advantages of reliable fixation, early functional exercise, and good functional recovery of the ankle joint.
-
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi · Sep 2015
[EFFECT OF MEDIAL 1/3 ANATOMICAL ORIENTATION OF TIBIAL TUBERCLE ON ROTATIONAL ALIGNMENT OF Gemini MK-II TIBIAL COMPONENTS IN TOTAL KNEE ARTHROPLASTY].
To investigate the effect of medial 1/3 anatomical orientation of the tibial tubercie on tne rotational alignment of Gemini MK-II tibial components in total knee arthroplasty (TKA). ⋯ In patients with varus knee osteoarthritis, medial 1/3 anatomical orientation of the tibial tubercle will contribute to the development of tibial rotational malalignment when TKA is performed by using Gemini MK-II tibial components.
-
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi · Sep 2015
[BIOMECHANICAL RESEARCH OF DIFFERENT INTERNAL FIXATIONS USING LOCKING RECONSTRUCTION PLATE FOR ACETABULAR TRANSVERSE FRACTURE].
To compare the biomechanical stability of acetabular transverse fracture fixed with single column locking reconstruction plate, locking reconstruction plate combined with lag screw, and double columns lag screws. ⋯ Locking reconstruction plate combined with lag screw and double columns lag screws have similar stability, they have stronger stability than the single column locking reconstruction plate. The stability of anterior column locking reconstruction plate is better than that of the posterior column locking reconstruction plate.
-
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi · Sep 2015
[COMPUTER ASSISTED DESIGN AND ELECTRON BEAMMELTING RAPID PROTOTYPING METAL THREE-DIMENSIONAL PRINTING TECHNOLOGY FOR PREPARATION OF INDIVIDUALIZED FEMORAL PROSTHESIS].
To study the feasibility of preparation of the individualized femoral prosthesis through computer assisted design and electron beammelting rapid prototyping (EBM-RP) metal three-dimensional (3D) printing technology. ⋯ Customized femoral prosthesis accurately matching with metaphyseal cavity can be designed through the thin slice CT scanning and computer assisted design technology. Titanium alloy personalized prosthesis with complex 3D shape, pore surface, and good matching with metaphyseal cavity can be manufactured by the technology of EBM-RP metal 3D printing, and the technology has convenient, rapid, and accurate advantages.