TheScientificWorldJournal
-
TheScientificWorldJournal · Jan 2014
Delay analysis of networked control systems based on 100 M switched Ethernet.
For the delay may degrade the performance of networked control systems, networked control systems based on 100 M switched Ethernet are proposed in this paper. According to the working principle of Ethernet switch, the formulas of the upper bound delay of the single-level switched Ethernet and the multiple-level switched Ethernet are deduced by the timing diagram method, and the values of the upper bound delay are also given. The key factors that influence the upper bound delay of switched Ethernet are analyzed; then, the characteristics of the upper bound delay are presented, which show that the delay induced by the single-level 100 M switched Ethernet has little effect on the performance of control systems, while the delay induced by the multiple-level 100 M switched Ethernet may meet the time requirements of all classes of control systems if the numbers of levels and the numbers of nodes connecting to switches are set properly. Finally, the performance of networked control systems is simulated by TrueTime, and the results further show the feasibility and superiority of 100 M switched Ethernet based networked control systems without modification of the network protocols.
-
TheScientificWorldJournal · Jan 2014
Alternative paradigm of selective vagus nerve stimulation tested on an isolated porcine vagus nerve.
Alternative paradigm for spatial and fibre-type selective vagus nerve stimulation (VNS) was developed using realistic structural topography and tested in an isolated segment of a porcine cervical left vagus nerve (LVN). A spiral cuff (cuff) containing a matrix of ninety-nine electrodes was developed for selective VNS. A quasitrapezoidal stimulating pulse (stimulus) was applied to the LVN via an appointed group of three electrodes (triplet). ⋯ Experimental testing of the paradigm showed the existence of certain parameters and waveforms of the stimulus, for which the contribution of the A-fibres to the NR was slightly reduced and that of the B-fibres was slightly enlarged. The cuff provided satisfactory fascicle discrimination in selective VNS as well as satisfactory fascicle discrimination during NR recording. However, in the present stage of development, fibre-type VNS remained rather limited.
-
TheScientificWorldJournal · Jan 2013
Epidural catheter placement in morbidly obese parturients with the use of an epidural depth equation prior to ultrasound visualization.
Previously, Balki determined the Pearson correlation coefficient with the use of ultrasound (US) was 0.85 in morbidly obese parturients. We aimed to determine if the use of the epidural depth equation (EDE) in conjunction with US can provide better clinical correlation in estimating the distance from the skin to the epidural space in morbidly obese parturients. ⋯ Use of the epidural depth equation (EDE) in conjunction with the longitudinal and transverse US views results in better clinical correlation than with the use of US alone.