Knee derangements: comparison of isotropic 3D fast spin-echo, isotropic 3D balanced fast field-echo, and conventional 2D fast spin-echo MR imaging.
To compare diagnostic performance, subjective image quality, and artifacts of isotropic three-dimensional (3D) intermediate-weighted (IW) fast spin-echo (SE), isotropic 3D balanced fast field-echo (FFE), and conventional two-dimensional (2D) fast SE 3.0-T MR sequences in evaluation of cartilage, ligaments, menisci, and osseous knee structures in symptomatic patients. ⋯ The performance of IW fast SE is superior to that of balanced FFE in evaluation of cartilaginous defects, with no significant difference in performance between 2D fast SE, 3D IW fast SE, and 3D balanced FFE in evaluation of meniscal and ligament tears. Subchondral bone marrow signal abnormality is more easily seen on 3D IW fast SE images, with better subjective image quality and fewer artifacts, than on images obtained with other techniques.
-
To determine the radiologic findings of human infection with a novel reassortant avian-origin influenza A H7N9 virus in March 2013, the first outbreak in humans. ⋯ Rapidly progressive GGOs and consolidations with air bronchograms and interlobular septal thickening, with right lower lobe predominance, are the main imaging findings in H7N9 pneumonia. The severity of these findings is associated with the severity of the clinical presentation.
-
To determine the time course of enhancement patterns in the aorta and endoleaks at dynamic computed tomographic (CT) angiography as well as their effect on the endoleak detection rate in patients who have undergone abdominal aortic endovascular aneurysm repair (EVAR). ⋯ Dynamic CT angiography revealed that the peak enhancement of endoleaks is significantly different than that of the aorta and that endoleaks may not be adequately evaluated with conventional biphasic CT protocols. The use of dynamic CT angiography is associated with a significantly increased detection rate of endoleaks compared with the detection rates at the time points of conventional biphasic CT.
-
To examine the associations between intracranial artery calcifications (IACs) and coronary artery calcifications (CACs) in patients with ischemic stroke and to assess the predictive value of IAC for asymptomatic coronary artery disease (CAD). ⋯ The IAC scores quantified by using unenhanced CT correlate significantly with coronary calcium scores and may serve as an independent predictor of asymptomatic CAD in patients with ischemic stroke.
-
To compare the diagnostic performance of dual-energy (DE) computed tomography (CT) with two simultaneously administered contrast agents (hereafter, dual contrast) with that of conventional CT in the evaluation of the presence and source of extravasation in penetrating abdominopelvic trauma. ⋯ In a rabbit abdominopelvic trauma model, dual-contrast DE CT significantly increased accuracy and confidence in the diagnosis of vascular versus enteric extravasated contrast material.