The Journal of extra-corporeal technology
-
J Extra Corpor Technol · Jun 2008
Influence of intraoperative fluid volume on cardiopulmonary bypass hematocrit and blood transfusions in coronary artery bypass surgery.
A hematocrit (Hct) of less than 25% during cardiopulmonary bypass (CPB) and transfusion of homologous packed red blood cells (PRBC) are each associated with an increased probability of adverse events in cardiac surgery. Although the CPB circuit is a major contributor to hemodilution intravenous (IV) fluid volume may also significantly influence the level of hemodilution. The objective of this study was to explore the influence of asanguinous IV fluid volume on CPB Hct and intraoperative PRBC transfusion. ⋯ Patients that received a PRBC transfusion (n = 30) received a significantly higher volume of pre-CPB fluid than nontransfused patients (1800 vs. 1350 mL, p = .0039). These findings suggest that pre-CPB fluid volume can significantly contribute to hemodilutional anemia in cardiac surgery. Optimizing pre-CPB volume may preserve baseline Hct and help limit intraoperative hemodilution.
-
J Extra Corpor Technol · Jun 2008
Case ReportsNovoseven use in a non-cardiac pediatric ECMO patient with uncontrolled bleeding.
Despite the presence of normal coagulation values, refractory bleeding during extracorporeal membrane oxygenation (ECMO) is encountered. Occasionally, hemostasis is not achieved through traditional techniques including surgical exploration, anti-fibrinolytics, increasing fibrinogen level, increasing platelet counts, and decreasing activated clotting time (ACT). We report the case of an infant on veno-arterial ECMO for respiratory syncytial virus with severe bleeding and the use of recombinant activated factor VII (rFVIIa; NovoSeven; Novo Nordisk, Copenhagen, Denmark). ⋯ Continued bleeding on ECMO unresponsive to current medical management may be an indication for rFVIIa. However, rFVIIa should not be administered without first considering the ECMO circuits conditions to include presence of clot, and documentation of circuit pressures, which, after rFVIIa, may be the first indication of intraoxygenator clot formation. Additionally, rFVIIa should not be a first-line treatment until continued studies allow for approved use in this patient population.
-
J Extra Corpor Technol · Mar 2008
Evaluation of the i-STAT point-of-care analyzer in critically ill adult patients.
Point-of-care analyzers may benefit therapeutic decision making by reducing turn-around-time for samples. This is especially true when biochemical parameters exceed the clinical reference range, in which acute and effective treatment is essential. We therefore evaluated the analytical performance of the i-STAT point-of-care analyzer in two critically ill adult patient populations. ⋯ In contrast to hematocrit measured during CPB, hematocrit using the non-CPB mode in the non-cardiac intensive care population showed an underestimation up to 2.2% (p < .0001) in the hematocrit range below 25% (n = 11) using the i-STAT. The i-STAT analyzer is suitable for point-of-care testing of electrolytes and blood gases in critically ill patients, except for high pO2. However, the discrepancy in hematocrit bias shows that accuracy established in one patient population cannot be automatically extrapolated to other patient populations, thus stressing the need for separate evaluation.
-
J Extra Corpor Technol · Dec 2007
ReviewAntifibrinolytic therapy: evidence, bias, confounding (and politics!).
Cardiac surgery can be complicated by postoperative bleeding and a need for blood transfusion and surgical reexploration. Anti-fibrinolytic drugs such as aprotinin and tranexamic acid may reduce bleeding risks but could possibly increase thrombotic complications. Aprotinin, in particular, has recently been implicated in at least two large observational studies, but this could be because it is more widely used in high-risk cardiac surgical patients. ⋯ Although multivariate adjustment and propensity score-matching can adjust for confounding, there is no certainty that it removes all such bias. For all anti-fibrinolytic drugs, it remains unclear as to whether the beneficial effect on reduced bleeding outweighs a possible increased risk of thrombotic complications. Debate will continue until we have the results of definitive large randomized trials powered to detect a clinically important effect on outcome.
-
J Extra Corpor Technol · Dec 2007
In vitro drug adsorption and plasma free hemoglobin levels associated with hollow fiber oxygenators in the extracorporeal life support (ECLS) circuit.
The purpose of this study was to identify the percentage of fentanyl or morphine sulfate lost from adhesion to either the polyvinylchloride (PVC) tubing or the surface of two different hollow fiber oxygenators used in current extracorporeal life support circuits and to identify any difference in the plasma free hemoglobin (PFH) levels generated when using these oxygenator and/or drug combinations. For each drug examined, six simple circuits were assembled; for each drug, two circuits contained tubing without an oxygenator (control), two circuits contained the Jostra Quadrox D (Maquet Cardiopulmonary, AG Hirrlingen, Germany), and two circuits contained the Terumo Baby Rx (Terumo Cardiovascular Systems Corp., Ann Arbor, MI). Fentanyl or morphine sulfate was added to yield initial circuit concentrations equal to 1430 ng/mL, respectively. ⋯ During this in vitro study, the majority of both drugs were lost to the PVC tubing. The type of oxygenator did not seem to significantly affect PFH. However, fentanyl in any combination or alone was associated with increased PFH levels.