Randomized Controlled TrialIn vivo comparison study of FDA-approved surface-modifying additives and poly-2-methoxyethylacrylate circuit surfaces coatings during cardiopulmonary bypass.
The purpose of this double-blind prospective and randomized study was to examine the effects of surface-modifying additives (SMAs) and poly-2-methoxyethylacrylate (PMEA) circuits on platelet count, platelet function (Sonoclot), postoperative chest tube drainage volume, peri- and postoperative blood product use, extubation time, and intensive care time. Terumo noncoated, Terumo-coated (PMEA), Cobe noncoated, and Cobe coated (SMA) circuits were evaluated to find the most cost-effective way to improve patient outcomes. We aimed to find if an additional charge for a coated CPB circuit would be recovered by reducing other patient costs (blood transfusions, intensive care unit time, and bring back postoperative bleeding). ⋯ This study provided evidence that SMA- and PMEA-coated circuits do not improve platelet consumption or decrease blood product use for patients undergoing CPB. There was statistical significance with a reduction in extubation time and total protamine requirement needed to return activated clotting time (ACT) to baseline post-CPB. Although the use of SMA and/or PMEA circuits during CPB has clinical benefit to the CPB patient, an additional charge for the specialty circuit may not be realized.
-
J Extra Corpor Technol · Mar 2006
Evaluation of biocompatible cardiopulmonary bypass circuit use during pediatric open heart surgery.
The contact of blood with nonbiological surfaces during cardiopulmonary bypass (CPB) induces a whole body inflammatory response and increases postoperative morbidity directly related to bleeding complications and end organ dysfunction. Methods to reduce these effects have included modification of extracorporeal circuits through biocompatible coating of disposables and the application of various pharmacological agents. Biocompatible coated surfaces are designed to mimic physiologic surfaces. ⋯ Statistical significance (p < .05) was seen in units of platelets transfused postprotamine, ventilator peak inflation pressure (PIP) on admission to the ICU, postoperative day 0 packed red blood cells (PRBC) and fresh frozen plasma (FFP) transfused, and lactate at 1, 2, 4, 6, and 12 hours postoperative. Several parameters approached statistical significance, including PRBC transfused postprotamine, time from protamine administration to chest closure, postoperative day 0 platelets transfused, and ICU stay. The data suggest that PMEA biocompatible CPB circuits can be used safely during pediatric heart surgery, resulting in a decrease in postoperative blood product use, improved postoperative lung function, and a reduction in the time spent in the ICU.