Journal of diabetes science and technology
-
J Diabetes Sci Technol · Sep 2014
Clinical TrialAccuracy of a novel noninvasive transdermal continuous glucose monitor in critically ill patients.
Stress hyperglycemia and hypoglycemia are associated with increased morbidity and mortality in the critically ill. Intermittent, random blood glucose (BG) measurements can miss episodes of hyper- and hypoglycemia. The purpose of this study was to determine the accuracy of the Symphony® continuous glucose monitor (CGM) in critically ill cardiac surgery patients. ⋯ No adverse device effects were reported. The Symphony CGM system is able to safely, continuously, and noninvasively monitor glucose in the transdermal interstitial fluid of cardiac surgery intensive care unit patients with accuracy similar to that reported with other CGM systems. Future versions of the system will need real-time data analysis, fast warm-up, and less frequent calibrations to be used in the clinical setting.
-
J Diabetes Sci Technol · Sep 2014
Reducing the risk of hypoglycemia associated with intravenous insulin: experience with a computerized insulin infusion program in 4 adult intensive care units.
Computerized insulin infusion protocols have facilitated more effective blood glucose (BG) control in intensive care units (ICUs). This is particularly important in light of the risks associated with hypoglycemia. End stage renal disease (ESRD) increases the risk of insulin-induced hypoglycemia. ⋯ Of ESRD patients, 41% had 1 or more BG < 79 mg/dL as compared with 17.8% of non-ESRD patients (P < .01). A higher BG target for medical ICU patients as compared with surgical ICU patients yielded comparably low rates of moderate or severe hypoglycemia. However, hypoglycemia among ESRD patients was more common compared to non-ESRD patients, suggesting a need for a higher BG target specific to ESRD patients.
-
J Diabetes Sci Technol · Jul 2014
ReviewGlucose control in the ICU: is there a time for more ambitious targets again?
During the last 2 decades, the treatment of hyperglycemia in critically ill patients has become one of the most discussed topics in the intensive medicine field. The initial data suggesting significant benefit of normalization of blood glucose levels in critically ill patients using intensive intravenous insulin therapy have been challenged or even neglected by some later studies. ⋯ Since increased risk of hypoglycemia appears to be the major obstacle of tight glucose control, we try to put forward novel approaches that may help to achieve optimal glucose control with low risk of hypoglycemia. If such approaches can be implemented in real-world practice the entire concept of tight glucose control may need to be revisited.
-
J Diabetes Sci Technol · Jul 2014
Clinical TrialApplication of PK/PD modeling and simulation to dosing regimen optimization of high-dose human regular U-500 insulin.
Pharmacokinetic/pharmacodynamic (PK/PD) studies of human regular U-500 insulin (U-500R) at high doses commonly used in clinical practice (>100 units) have not been performed. The current analysis applied PK/PD modeling/simulation to fit the data and simulate single-dose and steady-state PK/PD of U-500R high-dose regimens. Data from 3 single-dose euglycemic clamp studies in healthy obese and normal-weight patients, and normal-weight patients with type 1 diabetes were used to build the model. ⋯ PK/PD modeling/simulation of high U-500R doses supports BID or TID administration with an extended duration of activity relative to QD. TID dosing may provide slightly better full-day insulin effect. Additional PK/PD studies and randomized controlled trials of U-500R are needed to validate model predictions in patients with insulin-resistant diabetes requiring high-dose insulin.
-
J Diabetes Sci Technol · Jul 2014
Evaluation of intravascular microdialysis for continuous blood glucose monitoring in hypoglycemia: an animal model.
We have previously shown that intravascular microdialysis in a central vein is an accurate method for continuous glucose monitoring in patients undergoing cardiac surgery. However, no hypoglycemia occurred in our earlier studies, prompting further evaluation of the accuracy of intravascular microdialysis in the hypoglycemic range. Thus, this animal study was performed. ⋯ The microdialysis monitoring system was found to be very responsive in rapid changes in blood glucose concentration. This study shows that intravascular microdialysis in a central vein is an accurate method for continuous glucose monitoring in hypoglycemia in a porcine experimental model. Furthermore, the system was not influenced by glucose administration and was found to be responsive in rapid blood glucose fluctuations.