Comparative StudyTime-varying spectral analysis for comparison of HRV and PPG variability during tilt table test.
In this work we assessed the possibility of using the pulse rate variability (PRV) extracted from photoplethysmography signal as an alternative measurement of the HRV signal in non-stationary conditions. The study is based on the analysis of the changes observed during tilt table test in the heart rate modulation of 17 young subjects. Time-varying spectral properties of both signals were compared by time-frequency (TF) and TF coherence analysis. ⋯ Time-frequency analysis revealed that: the TF spectra of both signals were highly correlated (0.99 ± 0.01); the difference between the instantaneous power, in LF and HF bands, obtained from HRV and PRV was small (, 10(-3) s(-2)) and their temporal patterns were highly correlated (0.98 ± 0.04 and 0.95 ± 0.06 in LF and HF bands respectively); TF coherence in LF and HF bands was high (0.97 ± 0.04 and 0.89 ± 0.08, respectively). Finally, the instantaneous power in LF band was observed to significantly increase during head-up tilt by both HRV and PRV analysis. These results suggest that, although some small differences in the time-varying spectral indices extracted from HRV and PRV exist, mainly in the HF band associated with respiration, PRV could be used as an acceptable surrogate of HRV during non-stationary conditions, at least during tilt table test.
-
Conf Proc IEEE Eng Med Biol Soc · Jan 2010
Preliminary assessment of abdominal organ perfusion utilizing a fiber optic photoplethysmographic sensor.
In an attempt to overcome the limitations of current techniques for monitoring abdominal organ perfusion, a prototype reflectance fiber optic photoplethysmographic (PPG) sensor and processing system was evaluated on seventeen anaesthetized patients undergoing laparotomy. Good quality PPG signals were obtained from the large bowel, small bowel, liver and stomach. ⋯ Mean estimated blood oxygen saturation (SpO(2)) values from all abdominal sites showed good agreement with those obtained from the finger using both the finger fiber optic sensor and a commercial finger pulse oximeter. Furthermore, a Bland and Altman between-method-differences analysis on the estimated SpO(2) data suggests that a fiber optic abdominal sensor may be a suitable method for the evaluation of abdominal organ perfusion.
-
Conf Proc IEEE Eng Med Biol Soc · Jan 2010
Symbolic learning supporting early diagnosis of melanoma.
We present a classification analysis of the pigmented skin lesion images taken in white light based on the inductive learning methods by Michalski (AQ). Those methods are developed for a computer system supporting the decision making process for early diagnosis of melanoma. ⋯ Classification performance with the wavelet features, although achieved with simple rules, is very high. Symbolic learning applied to our skin lesion data seems to outperform other classical machine learning methods, and is more comprehensive both in understanding, and in application of further improvements.
-
Conf Proc IEEE Eng Med Biol Soc · Jan 2010
Real time breathing rate estimation from a non contact biosensor.
An automated real time method for detecting human breathing rate from a non contact biosensor is considered in this paper. The method has low computational and RAM requirements making it well-suited to real-time, low power implementation on a microcontroller. ⋯ On a 1s basis, 96% of breaths were scored within 1 breath per minute of expert scored respiratory inductance plethysmography, while 99% of breaths were scored within 2 breaths per minute. When averaged over 30s, as is used in this respiration monitoring system, over 99% of breaths are within 1 breath per minute of the expert score.
-
Conf Proc IEEE Eng Med Biol Soc · Jan 2010
Electroconvulsive therapy in the presence of deep brain stimulation implants: electric field effects.
The safety of electroconvulsive therapy (ECT) in patients who have deep brain stimulation (DBS) implants represents a significant clinical issue. A major safety concern is the presence of burr holes and electrode anchoring devices in the skull, which may alter the induced electric field distribution in the brain. We simulated the electric field using finite-element method in a five-shell spherical head model. ⋯ We compared electric field strength and focality among the DBS implantation techniques and ECT electrode configurations. The simulation results show an increase in the electric field strength in the brain due to conduction through the burr holes, especially when the burr holes are not fitted with nonconductive caps. For typical burr hole placement for subthalamic nucleus DBS, the effect on the electric field strength and focality is strongest for BF ECT, which runs contrary to the belief that more anterior ECT electrode placements are safer in patients with DBS implants.