Development of modified intraoperative examination monitor for awake surgery (IEMAS) system for awake craniotomy during brain tumor resection.
Gliomas represent the most frequent type of primary intracranial tumors, which originate from the brain tissue itself, have infiltrative growth, unclear borders, and usually affect functionally-important cerebral structures. From March 2000 till March 2010, 839 neurosurgical procedures directed on resection of such neoplasms were performed in the intelligent operating theater of Tokyo Women's Medical University with the use of intraoperative MRI, real-time updated neuronavigation system, and Hi-vision operative microscope. To facilitate maximal possible tumor resection with minimal risk of neurological morbidity a special device, called Intraoperative Examination Monitor for Awake Surgery (IEMAS) was developed by us. ⋯ The clinical testing of t- - his system was initiated on February 1, 2010, but quickly revealed crossed line effect between transmitters and receivers. To overcome this obstacle and to isolate transmitters, one channel was changed from wireless connection into wired, which resulted in significant improvement of the clearness of both transmitted images and sounds, and provides an opportunity for effective clinical use of the device. In perspective we wish to make IEMAS system fully wireless, using several types of frequency range transmitters.
-
Conf Proc IEEE Eng Med Biol Soc · Jan 2010
PhysioDoloris: a monitoring device for analgesia / nociception balance evaluation using heart rate variability analysis.
Continuous Analgesia / Nociception balance evaluation during general anesthesia could be of precious help for the optimization of analgesic drugs delivery, limiting the risk of toxicity due to the use of opioid drugs, limiting the risk of post operative hyper algesia, and, probably, reducing time of recovery after surgical procedure. Heart Rate Variability analysis has been shown in several studies to measure the Autonomic Nervous System tone, which is strongly influenced by anesthetic drugs. ⋯ We have previously developed and evaluated a pain / analgesia measurement algorithm based on the magnitude analysis of the respiratory patterns on the RR series. In this paper, we present the development of a monitoring device (PhysioDoloris), based on the previously described technology, giving in real time an Analgesia Nociception Index (ANI) which can be used during general anesthesia in order to give to the anesthetist, a complementary tool for optimized drug delivery.
-
Conf Proc IEEE Eng Med Biol Soc · Jan 2010
Development of a data acquisition and analysis system for nociceptive withdrawal reflex and reflex receptive fields in humans.
A system for data acquisition and analysis of nociceptive withdrawal reflex (NWR) and reflex receptive field (RRF) is introduced. The system is constituted by hardware and software components. ⋯ These programs were developed to maximize the potential of the hardware, turning it into a complete stimulation system capable of automatic quantification of NWR and RRF. In this article, a brief review of NWR and RRF analysis is presented, the system features are described in detail and its present and future applications are discussed.
-
Conf Proc IEEE Eng Med Biol Soc · Jan 2010
Anaesthesia synchronization software: target controlled infusion system evaluation.
Target Controlled Infusion (TCI) systems are based in drug Pharmacokinetic (Pk) and Pharmacodynamic (Pd) models implemented in an algorithm to drive an infusion device. Several studies had compare manual titration of anesthesia and TCI system use; some studies evaluate the performance of the control algorithms for TCI systems, and a considerable number of studies assess the performance of Pk/Pd models implemented into TCI systems. ⋯ The goal of the current study was to assess the performance of the TCI system, Anaesthesia Synchronization Software (ASYS), on clinical set up to evaluate communication consistence (computer - infusion device) and controller performance in real time. These measures provided quantitative and qualitative evidences of software robustness and accuracy to be used at clinical environment.
-
Conf Proc IEEE Eng Med Biol Soc · Jan 2010
Effect of ECG quality measures on piecewise-linear trend detection for telehealth decision support systems.
Fledgling clinical decision support systems (DSSs) are being designed on the false assumption that consistent, good-quality signals are created in the unsupervised telehealth environment, but it has in fact been shown that signal quality is often very poor. Hence, it is important to investigate the detrimental impact of failing to recognize erroneous clinical parameter values. ⋯ The application of the same artifact detection also results in a significant improvement in trend fitting, when compared to a fitting of the reference HR values, by reducing the mean RMSE value of the error in the trend fit from 2.14 BPM to 0.78 BPM and standard error from 0.49 BPM to 0.10 BPM. As trend detection will be a component of future telehealth decision support systems, signal quality measures for unsupervised measurements are of paramount importance.