Journal of orthopaedic surgery and research
-
We reviewed our results and complications of using a pre-bent 1.6 mm Kirschner wire (K-wire) for extra-articular metacarpal fractures. The surgical procedure was indicated for angulation at the fracture site in a true lateral radiograph of at least 30 degrees and/or in the presence of a rotatory deformity. ⋯ With this simple and minimally invasive technique performed as day-case surgery, all patients were able to start mobilisation immediately. The general outcome was good hand function with few complications.
-
Osteoporotic vertebral compression fractures are a menace to the elderly generation causing diminished quality of life due to pain and deformity. At first, conservative treatment still is the method of choice. In case of resulting deformity, sintering and persistent pain vertebral cement augmentation techniques today are widely used. ⋯ Polymethyl methacrylate (PMMA)-cement should be favoured, since calcium phosphate cement showed inferior biomechanical properties and less effect on pain reduction especially in less stable burst fractures. Common complications of kyphoplasty are cement leakage and adjacent segment fractures. Rare complications are toxic PMMA-monomer reactions, cement embolisation, and infection.
-
Case Reports Comparative Study
The calcar screw in angular stable plate fixation of proximal humeral fractures--a case study.
With new minimally-invasive approaches for angular stable plate fixation of proximal humeral fractures, the need for the placement of oblique inferomedial screws ('calcar screw') has increasingly been discussed. The purpose of this study was to investigate the influence of calcar screws on secondary loss of reduction and on the occurrence of complications. ⋯ The placement of calcar screws in the angular stable plate fixation of proximal humeral fractures is associated with less secondary loss of reduction by providing inferomedial support. An increased risk for complications could not be shown.
-
Comparative Study
A comparison of two headless compression screws for operative treatment of scaphoid fractures.
The purpose of this study was to compare the interfragmentary compression force across a simulated scaphoid fracture by two commonly used compression screw systems; the Acutrak 2 Standard and the 3.0 mm Synthes headless compression screw. ⋯ Peak interfragmentary compression observed during screw installation was similar for both screw systems. However, the mean interfragmentary compression generated by the Acutrak 2 Standard was significantly greater. Our study demonstrates that the Synthes headless compression screw experienced a greater loss of interfragmentary compressive force from the time of installation to the final steady state compression level. The higher post-installation compression of the Acutrak 2 Standard may be attributable to the greater number of threads throughout the entire length of the screw. The clinical significance of these results, are, at this point uncertain. We do demonstrate that a fully threaded design offers a more reliable compression that may translate to more predictable bony union.
-
Flexible intramedullary nailing has emerged as an accepted procedure for paediatric femoral fractures. Present indications include all patients with femoral shaft fractures and open physis. Despite its excellent reported results, orthopaedic surgeons remain divided in opinion regarding its usefulness and the best material used for nails. We thus undertook a retrospective study of paediatric femoral fractures treated with titanium or stainless steel flexible nails at our institute with a minimum of 5 years follow up. ⋯ Flexible intramedullary nailing is reliable and safe for treating paediatric femoral shaft fractures. It is relatively free of serious complications despite asymptomatic malalignment and LLD in significant percentage of fractures.