Journal of the American Heart Association
-
E-cigarette or vaping product use-associated lung injury was recognized in the United States in the summer of 2019 and is typified by acute respiratory distress, shortness of breath, chest pain, cough, and fever, associated with vaping. It can mimic many of the manifestations of coronavirus disease 2019 (COVID-19). ⋯ Lung lesions included thickening of the alveolar wall with foci of inflammation, red blood cell congestion, obliteration of alveolar spaces, and pneumonitis in some cases; bronchi showed accumulation of fibrin, inflammatory cells, and mucus plugs. Electronic cigarette users should be cautioned about the potential danger of operating electronic cigarette units at high settings; the possibility that certain heating elements may be deleterious; and that E-cigarette or vaping product use-associated lung injury may not be dependent upon tetrahydrocannabinol, vitamin E, or nicotine.
-
Multicenter Study Clinical Trial
Atrial Arrhythmias in Clinically Manifest Cardiac Sarcoidosis: Incidence, Burden, Predictors, and Outcomes.
Background Recent data have suggested a substantial incidence of atrial arrhythmias (AAs) in cardiac sarcoidosis (CS). Our study aims were to first assess how often AAs are the presenting feature of previously undiagnosed CS. Second, we used prospective follow-up data from implanted devices to investigate AA incidence, burden, predictors, and response to immunosuppression. ⋯ Second, AAs occurred in a minority of patients at follow-up; the burden was very low in most patients. Only 2 patients had clinically significant AA burden, and both had a reduction after CS was treated. Registration URL: https://www.clinicaltrials.gov; unique identifier NCT01477359.
-
Comparative Study Clinical Trial
Effect of Optimized Versus Guidelines-Based Automated External Defibrillator Placement on Out-of-Hospital Cardiac Arrest Coverage: An In Silico Trial.
Background Mathematical optimization of automated external defibrillator (AED) placement may improve AED accessibility and out-of-hospital cardiac arrest (OHCA) outcomes compared with American Heart Association (AHA) and European Resuscitation Council (ERC) placement guidelines. We conducted an in silico trial (simulated prospective cohort study) comparing mathematically optimized placements with placements derived from current AHA and ERC guidelines, which recommend placement in locations where OHCAs are usually witnessed. Methods and Results We identified all public OHCAs of presumed cardiac cause from 2008 to 2016 in Copenhagen, Denmark. ⋯ Estimated bystander defibrillation and 30-day survival rates increased from 15.6% to 18.2% (P<0.05) and from 32.6% to 34.0% (P<0.05), respectively. As a baseline, the 1573 real AEDs in Copenhagen covered 14.4% of the OHCAs. Conclusions Mathematical optimization can significantly improve OHCA coverage and estimated clinical outcomes compared with a guidelines-based approach to AED placement.