We report a patient who presented with multiple rib fractures after falling off a horse and was initially managed medically. Several weeks later, the patient returned to the hospital complaining of dyspnea on exertion. ⋯ The procedures were performed using both intra-thoracic and extra-thoracic video-assisted thoracoscopic surgery (VATS) and did not require the use of thoracotomy incision or open exposure of the thoracic cavity. This case report suggests that this operative technique is a viable option for delayed presentation of multiple rib fractures and complex sequela associated with this pathology.
-
The aim of this study is to evaluate the biomechanical effect of filling locking variable angle (VA) screw holes at the area of metaphyseal fracture comminution in a Sawbones® (Sawbones USA, Vashon, Washington) model (AO/OTA 33A-3 fracture) using a Synthes VA locking compression plate (LCP) (Depuy Synthes, Warsaw, Indiana). ⋯ The Synthes VA-LCP in a simulated AO/OTA 33-A3 comminuted metaphyseal femoral fracture fails in a reproducible manner at the area of comminution through the "honeycomb" VA screw holes. Filling open VA screw holes at the site of comminution with locking screws does not increase fatigue life of the Synthes VA-LCP in a simulated AO/OTA 33-A3 distal femoral fracture. Further studies are necessary to determine whether use of this particular plate is contraindicated when bridging distal femoral fractures with metaphyseal comminution.
-
Anastomotic leakage is a severe complication after colonic/rectal surgery. One of the most important causes of anastomotic leakage is poor vascular supply. However, microvascular impairment at the anastomotic site is very often not detected intraoperatively by observation under white light. ⋯ This may be useful for intraoperatively changing a previously planned resection/anastomotic level, and conceivably decreasing the degree of anastomotic leakage. At this stage, even though ICG technology appears to be very promising and some preliminary clinical studies have suggested that certain ICG pharmacokinetic parameters may be used to predict leakage, more reliable scoring and grading tools are needed. Furthermore, in minimally invasive colorectal surgery, more randomized prospective well-powered trials are needed to properly standardize this surgical technology.
-
Fibular head avulsion fractures are rare injuries determined by traction of the fibular attachment of the lateral collateral ligament (LCL). Surgical treatment is often recommended with different techniques such as tension band fixation or lag screws stabilization. In this article, we describe a fixation technique of fibular head fractures obtained through the use of anchors. ⋯ He reported a complex injury of the posterolateral corner with an avulsion fracture of the left fibular head. We performed a clinical evaluation at the final follow-up visit (six months). We demonstrated that the use of suture anchors may be an effective technique of fixation in avulsion fracture of the fibular head associated with combined posterolateral corner injuries.
-
Due to advances in neoadjuvant therapies and preoperative imaging modalities, joint-sparing resections have become appealing in bone tumor surgery. However, the intercalary reconstruction of metadiaphyseal bone defects of the femur and the tibia after juxta-articular tumor resection remains challenging. Both biological and prosthetic reconstructions have been used for joint-sparing resections, but little is known about the long-term outcome of these procedures. ⋯ Biologic intercalary reconstructions with bone grafts resulted in effective joint-sparing resections of the lower limb, allowing joint preservation in all but one case who required a total knee replacement for varus osteoarthritis. Despite the high rate of complications requiring surgical revision, at 15 years, overall survival of the reconstruction was 90% and limb salvage survival was 94%. In our experience, revision-free survival was better with VFG reconstruction than with allograft alone and the combination of VFG and allogenic graft seems to favor spontaneous fracture-healing and to decrease the non-union rate.