Ultrasound in medicine & biology
-
Ultrasound Med Biol · May 2015
An ultrasonographic technique to assess the jugular venous pulse: a proof of concept.
The purpose of the work described here was to investigate the feasibility of assessing the jugular venous pulse (JVP) using ultrasound (US) equipment. Three young healthy subjects underwent a B-mode US scan of the internal jugular vein (IJV) to acquire a sonogram sequence in the transverse plane. On each acquired sonogram, the IJV contour was manually traced, and both the cross-sectional area (CSA) and the perimeter were measured. ⋯ We compared 390 manually traced contours of the IJV cross-sectional area with corresponding values semi-automatically calculated by an algorithm developed in-house. For all subjects, the sensitivity, specificity and accuracy were around 95%, 85% and 90% respectively. We found that a diagram reflecting the JVP can be obtained by analyzing a B-mode sonogram sequence of the IJV; such a diagram can result in a new methodology to assess the IJV functionality.
-
Ultrasound Med Biol · May 2015
Comparative StudyImproved correlation between carotid and coronary atherosclerosis SYNTAX score using automated ultrasound carotid bulb plaque IMT measurement.
Described here is a detailed novel pilot study on whether the SYNTAX (Synergy between percutaneous coronary intervention with TAXUS and cardiac surgery) score, a measure of coronary artery disease complexity, could be better predicted with carotid intima-media thickness (cIMT) measures using automated IMT all along the common carotid and bulb plaque compared with manual IMT determined by sonographers. Three hundred seventy consecutive patients who underwent carotid ultrasound and coronary angiography were analyzed. SYNTAX score was determined from coronary angiograms by two experienced interventional cardiologists. ⋯ This current automated algorithm revealed a significantly stronger correlation between cIMT and coronary SYNTAX score as compared with the sonographer's cIMT measurements with multiple cardiovascular risk factors. We benchmarked our correlation between the automated cIMT that includes bulb plaque and SYNTAX score against a previously published (Ikeda et al. 2013) AtheroEdgeLink (AtheroPoint) correlation between the automated cIMT that does not include bulb plaque and SYNTAX score and had an improvement of 44.58%. By sampling cIMT in the bulb region, the automated cIMT technique improves the degree of correlation between coronary artery disease lesion complexity and carotid atherosclerosis characteristics.
-
Ultrasound Med Biol · Apr 2015
Feasibility and usefulness of using swallow contrast-enhanced ultrasound to diagnose Zenker's diverticulum: preliminary results.
Zenker's diverticulum (ZD) may be misdiagnosed on conventional ultrasound as a thyroid nodule or other lesion. A barium esophagram is usually used to confirm the diagnosis; however, this procedure exposes the patient to radiation. The aim of this study was to evaluate the feasibility of using swallow contrast-enhanced ultrasound (swallow-CEUS) to diagnose ZD. ⋯ The barium esophagram confirmed the diagnosis of ZD in all patients. For the 10 volunteers, no abnormal structure (retaining UCA) was detected during or after swallowing of UCA. With the advantages of no radiation and bedside availability, swallow-CEUS may become a method of choice in confirmation of the diagnosis of ZD, especially when ZD is suspected on conventional ultrasound.
-
Ultrasound Med Biol · Apr 2015
Assessment of the safety and efficacy of bedside ultrasound guidance for inferior vena cava filter placement in critically ill intensive care unit patients.
Inferior vena cava filters (IVCFs) have been used clinically for approximately 45 y, but only a few studies of these devices have involved intensive care unit (ICU) patients who were critically ill and had multiple-organ dysfunction or were otherwise too unstable for transport. The purpose of this research was to assess the tolerability and efficacy of bedside ultrasound-guided IVCF placement in ICU patients. A retrospective analysis of both bedside ultrasound-guided and X-ray-guided ICVF placement was performed from November of 2011 to August of 2013. ⋯ IVCFs may be safely implanted under ultrasound guidance in a monitored ICU environment. Our conclusion is that patients should be fasting and should receive an enema and that pre-operative surface marking and dynamic monitoring should be employed. Further research is needed to develop specific ultrasound guidelines.
-
Ultrasound Med Biol · Feb 2015
Randomized Controlled TrialUsing critical care chest ultrasonic examination in emergency consultation: a pilot study.
The purpose of this study was to investigate the effects of critical care chest ultrasonic examination (CCUE) by intensivist on the diagnosis and treatment decisions in emergent consultation for patients who may have a problem-need transfer to an intensive care unit (ICU). A total of 130 patients who required emergent consultation in the ordinary wards were included in this study. ⋯ The CCUE group had a shorter time to preliminary diagnosis, final diagnosis, treatment response and X-ray/computed tomography examination; a delay in ICU transfer and ICU stay days (3.9 ± 1.2 vs. 5.4 ± 1.9 d, p < 0.05) and a higher diagnostic accuracy than the conventional group (p < 0.001). In conclusion, CCUE could help early diagnosis and therapy for the patient who may need to transfer to the ICU and reduce the ICU stay for in-hospital patients in emergent consultation.