Pulsed Ultrasound Remedies Post-thoracotomy Hypersensitivity and Increases Spinal Anti-inflammatory Cytokine in Rats.
The purpose of the experiment was to study the effect of pulsed ultrasound (PUS) on post-thoracotomy pain and local tissue temperature and to correlate the findings with the alteration in spinal anti-inflammatory and pro-inflammatory cytokines. Mechanical sensitivity, subcutaneous temperature and spinal interleukin-10 (IL-10), IL-6 or tumor necrosis factor-alpha (TNF-α) expression were examined in a rat model of experimental post-thoracotomy pain. Group 1 received a sham surgery where thoracotomy was performed except for rib retraction. ⋯ We concluded that mechanical hypersensitivity after TRR is postponed by PUS, and its effect continues for 3 wk. A PUS dose not increase local tissue temperature. The beneficial effect of PUS appears related to upregulation of spinal anti-inflammatory cytokine and downregulation of spinal pro-inflammatory cytokines.
-
Ultrasound Med Biol · Dec 2020
Comparative StudyComparison of Linear and Sector Array Probe for Handheld Lung Ultrasound in Invasively Ventilated ICU Patients.
International guidelines do not recommend a specific probe for assessment of lung aeration using lung ultrasound (LUS). The aim of this study was to assess the concordance between linear and sector array probes of a handheld ultrasound device in assessment of lung aeration in invasively ventilated intensive care unit patients. This study included intensive care unit patients who were expected to be ventilated for longer than 24 h. ⋯ ICCs calculated for the remaining images revealed good concordance the LUS aeration scores for individual images (ICC = 0.73, 95% confidence interval 0.67-0.78), number of B-lines (ICC = 0.79, 95% confidence interval 0.72-0.83) and global LUS aeration score (ICC = 0.74, 95% confidence interval 0.52-0.87). In conclusion, there is good concordance between linear and sector array probes of a handheld ultrasound device in assessment of lung aeration patterns in mechanically ventilated intensive care unit patients. However, in roughly 10% of the images acquired using the linear probe, the aeration pattern could not be scored.
-
Ultrasound Med Biol · Nov 2020
Observational StudyReliability and Agreement of Point and 2-D Shear-Wave Elastography in Assessing the Sciatic Nerve Stiffness.
Information is lacking about the reliability and agreement of different shear-wave elastographic modes in the peripheral nervous system evaluation. The aim of this observational study was to evaluate reproducibility and agreement of two different shear-wave elastographic modes for measuring the sciatic nerve stiffness in patients affected by osteoarthrosis. Two sets of three measurements were conducted bilaterally on the sciatic nerve of 20 patients with point and 2-D shear-wave elastography by a unique expert sonographer. ⋯ Correlation between the two sets of measurements was good and excellent (0.799 with point shear-wave elastography and 0.877 with 2-D shear-wave elastography). Intra-class coefficient correlation between the two sets of measurements was excellent for both shear-wave elastographic modes (0.869 and 0.938, respectively); no agreement between them was demonstrated (analysis of variance [ANOVA] test: p = 0.014). Despite the lack of agreement owing to the different procedures for measuring, both shear-wave elastographic modes allow reliable stiffness measurements of the sciatic nerve and may be used to evaluate stiffness changes.
-
Ultrasound Med Biol · Nov 2020
Lung Ultrasound Score in Evaluating the Severity of Coronavirus Disease 2019 (COVID-19) Pneumonia.
The purpose of this study is to observe the potential of lung ultrasound in evaluating the severity of coronavirus disease 2019 (COVID-19) pneumonia. Lung ultrasound was performed in ten zones of the patients' chest walls. The features of the ultrasound images were observed, and a lung ultrasound score (LUS) was recorded. ⋯ The LUS was significantly higher in the refractory group (33.00 [IQR 27.50-34.00] vs. 25.50 [IQR 22.75-30.00]). The ROC of the LUS showed a cutoff score of 32 with a specificity of 0.893 and a sensitivity of 0.571 in diagnosing refractory respiratory failure among patients. In COVID-19 patients, lung ultrasound is a promising diagnostic tool in diagnosing patients with refractory pneumonia.
-
Ultrasound Med Biol · Nov 2020
ReviewLung Ultrasound May Support Diagnosis and Monitoring of COVID-19 Pneumonia.
Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) disease (COVID-19) is characterized by severe pneumonia and/or acute respiratory distress syndrome in about 20% of infected patients. Computed tomography (CT) is the routine imaging technique for diagnosis and monitoring of COVID-19 pneumonia. Chest CT has high sensitivity for diagnosis of COVID-19, but is not universally available, requires an infected or unstable patient to be moved to the radiology unit with potential exposure of several people, necessitates proper sanification of the CT room after use and is underutilized in children and pregnant women because of concerns over radiation exposure. ⋯ Compared with CT, LUS has several other advantages, such as lack of exposure to radiation, bedside repeatability during follow-up, low cost and easier application in low-resource settings. Consequently, LUS may decrease utilization of conventional diagnostic imaging resources (CT scan and chest X-ray). LUS may help in early diagnosis, therapeutic decisions and follow-up monitoring of COVID-19 pneumonia, particularly in the critical care setting and in pregnant women, children and patients in areas with high rates of community transmission.