Transfusion
-
This report describes the first year of a government-sponsored program that uses daily reports from 29 sentinel sites to monitor the capacity of the US blood supply to meet demand. ⋯ Inventories of RBCs maintained at the participating sites were sufficient, with only one brief exception, to meet local demand during the first year of this monitoring program. The weekly rate of threatened shortage reports was more sensitive than days inventory as a predictor of actual shortages of RBCs. Unlike RBCs, platelet days supply, reports of threatened or actual platelet shortages, and platelet outdate rates did not vary seasonally.
-
Comparative Study
Statistical analysis of inappropriate results from current Hb screening methods for blood donors.
The objective was to apply statistical analysis to the false passes and fails that occur with the primary and secondary Hb-screening methods used at blood-donor sessions. ⋯ CuSO4 Hb screening gives large numbers of false passes, particularly in women. Using venous samples, the majority correctly pass at the lower HemoCue cut-offs. The current dual-testing policy appears convenient for donor sessions, but because small percentages of false passes and fails represent large numbers of donors, every effort should be made to improve the accuracy of Hb screening.
-
The cardiovascular response to acute isovolemic anemia in humans is thought to differ from that of other species. Studies of anesthetized humans have found either no change or a decreased heart rate. A previous study showed that in 32 healthy unmedicated humans, heart rate increased during acute isovolemic anemia. The hypothesis that heart rate in humans increases in response to acute isovolemic anemia and that the increase is affected by gender was tested. ⋯ In 95 unmedicated, healthy humans, heart rate was a linear function of Hb during acute isovolemic anemia. Females had a significantly greater slope of increase in heart rate with decreasing Hb concentration than did males. The relationship is consistent among individuals, is similar to that reported for conscious dogs, and differs from that found previously in anesthetized humans.
-
TRALI is thought to be triggered by recipient-specific anti-HLA class I or antibodies against neutrophils in donor plasma. Recently, anti-HLA class II have also been implicated. The prevalence of anti-HLA class II was investigated in normal volunteer platelet donors and in two nonfatal TRALI cases utilizing a flow-based assay. Potential target antigens also were investigated. ⋯ FlowPRA assays often detect anti-HLA class I not detected by conventional lymphocytotoxicity assays. These assays reveal anti-HLA class II in normal female donor plasma and in sera implicated in TRALI. Immunohistochemical studies failed to reveal endothelial or intravascular-WBC HLA class II antigen expression in lung tissue derived from TRALI cases or controls, but demonstrated HLA class II expression on pulmonary macrophages.
-
Tick-borne diseases, particularly babesiosis and ehrlichiosis, represent recently emerging infections. Despite an increased recognition of the threat tick-borne agents pose to blood safety, our understanding of the prevalence and transmissibility of these agents in blood donors is limited. ⋯ Blood donors seropositive for B. microti and A. phagocytophila are present in Connecticut and Wisconsin. Donors readily recall previous tick bites, but self-reported bites are not reliable indicators of serologic status. The exposure of blood donors to tick-borne pathogens does suggest a need to better understand the transfusion transmission potential of these agents.