First prospective, multi-centre clinical experience with a novel left ventricular quadripolar lead.
Cardiac resynchronization therapy (CRT) is sometimes complicated by elevated pacing thresholds and phrenic nerve stimulation (PNS), both of which may require that the coronary sinus lead be repositioned. The purpose of this study was to evaluate the performance of a novel quadripolar electrode lead and cardiac resynchronization therapy-defibrillator (CRT-D) device that enables electrical repositioning, potentially obviating a lead reposition procedure. ⋯ The new quadripolar electrode LV lead provides more programming options to address common problems faced when managing CRT patients. Electrical measurements from new vectors are comparable with conventional configurations. Furthermore, 11% of patients in the study suffered PNS on all conventional bipolar vectors.
-
The use of implantable cardioverter defibrillators (ICD) in patients with torsade de pointes (TdP) and ventricular fibrillation in the presence of acquired long QT syndrome (aLQTS) is under debate, partly due to the fact that aLQTS is potentially reversible and currently no long-term follow-up data are available. We aimed to evaluate the long-term follow-up of patients with acquired long QT syndrome (aLQTS) who had received an implantable cardioverter defibrillator (ICD) for secondary prevention of sudden cardiac arrest (SCA). ⋯ Appropriate ICD shocks are a common finding in patients with aLQTS and SCA irrespective of the underlying cause or structural heart disease. Thus, even in the presence of relevant acquired proarrhythmia ICD may be beneficial.
-
Patients can expect a cure from atrial fibrillation (AF) with ablation. Procedural safety and success depend on patient comfort, compliance, and immobility. This is difficult to achieve with benzodiazepine and opiate boluses that are the mainstay of current practice. We sought to determine the safety and efficacy of propofol infusion sedation administered to patients without assisted ventilation for AF ablation. ⋯ Sedation with 2% propofol infusion administered by cardiologists without assisted ventilation is safe, effective, and practical for use in AF ablation without serious or residual complications. In this setting, persistent hypotension is the most common acute adverse effect requiring cessation of propofol in ∼14%.
-
Case Reports
Intramural inflammation as a cause of transient ST-segment elevation in a patient of cardiac sarcoidosis.
Cardiac magnetic resonance demonstrated myocardial damage within the left ventricle (LV) in a patient with cardiac sarcoidosis. During inflammation, ST-segment elevation was observed in her ECG. The ST-segment deviation was attenuated following disappearance of the abnormal Gallium-67 uptake in the LV, suggesting transmural LV voltage gradient was a cause of the ST-segment elevation.