Diabetes technology & therapeutics
-
Diabetes Technol. Ther. · Jun 2004
Experience with the continuous glucose monitoring system in a medical intensive care unit.
Strict glycemic control improves clinical outcomes in critically ill patients. However, practical tools for frequent monitoring of blood glucose (BG) levels in the intensive care unit (ICU) are limited. The Continuous Glucose Monitoring System (CGMS, Medtronic MiniMed, Northridge, CA) is currently approved for detecting glycemic excursions in outpatients with diabetes mellitus. ⋯ The CGMS is promising for potential use in critically ill patients. If validated in larger studies, the device could serve as a useful research tool for investigating the role of hyperglycemia (and strict glycemic control) in ICU patients. If further developed as a "real-time" glucose sensor, CGMS technology could ultimately prove clinically useful in the ICU, by decreasing nursing workload and/or by providing alarm signals for impending glycemic excursions.
-
Diabetes Technol. Ther. · Apr 2004
Randomized Controlled Trial Clinical TrialImpact of particle size and aerosolization time on the metabolic effect of an inhaled insulin aerosol.
The effects were compared of varying aerosol particle size and aerosolization time within each breath on the metabolic effect elicited by inhalation of a liquid insulin aerosol in comparison with that after subcutaneous injection (s.c.) of regular insulin. In this single-center, open-label euglycemic glucose clamp study, 13 healthy non-smoking subjects received five administrations of insulin in randomized order on separate study days, once by s.c. (0.15 U/kg of regular insulin) and four times by inhalation. Subjects inhaled 1.5 U/kg of liquid insulin aerosol administered by the Aerodose Insulin Inhaler (Aerogen Inc., Mountain View, CA) configured to deliver two aerosol particle sizes--fine [F, 4.4 +/- 0.3 microm (mean +/- SD)] or very fine (VF, 3.5 +/- 0.2 microm)--and two aerosolization times (aerosol released for the first 2 or 4 s after the start of each 5-s inhalation). ⋯ No drug- or device-related adverse events were observed. This study shows that aerosolization time, but not particle size, in the ranges studied, had an impact on the metabolic effect elicited by inhaled insulin, allowing rational selection of delivery parameters for further clinical testing. Based on the observed biopotency and the rapid onset of action, inhalation of a liquid insulin aerosol generated by the Aerodose Insulin Inhaler shows promise for covering prandial insulin requirements.
-
Diabetes Technol. Ther. · Apr 2004
Randomized Controlled Trial Clinical TrialAlarms based on real-time sensor glucose values alert patients to hypo- and hyperglycemia: the guardian continuous monitoring system.
The purposes of this study were to demonstrate the accuracy and effectiveness of the Guardian Continuous Monitoring System (Medtronic MiniMed, Northridge, California) and to demonstrate that the application of real-time alarms to continuous monitoring alerts users to hypo and hyperglycemia and reduces excursions in people with diabetes. A total of 71 subjects with type 1 diabetes, mean hemoglobin A1c of 7.6 +/- 1.1%, age 44.0 +/- 11.4 years, and duration of diabetes 23.6 +/- 10.6 years were enrolled in this two-period, randomized, multicenter study. Subjects were randomized into either an Alert group or a Control group. ⋯ A marginally significant increase in the frequency of hyperglycemic excursions (P = 0.07) between Period 1 and Period 2 was accompanied by a decrease of 9.6 min in the duration of hyperglycemic excursions in the Alert group. Glucose measurements differ between blood samples taken from the finger and interstitial fluid, especially when levels are changing rapidly; however, these results demonstrate that the Guardian is reasonably accurate while performing continuous glucose monitoring. The subjects' responses to hypoglycemia alerts resulted in a significant reduction in the duration of hypoglycemic excursions; however, overtreating hypoglycemia may have resulted in a marginally significant increase in the frequency of hyperglycemic excursions.
-
Diabetes Technol. Ther. · Jan 2003
Comment Case ReportsInadvertent sulfonylurea overdosage and hypoglycemia in an elderly woman: failure of serum hypoglycemia screening.
We report a case of an 82 year-old woman who had two episodes of documented hypoglycemia. Initial laboratory testing revealed hyperinsulinemia and a negative serum sulfonylurea screen. While these data suggested the presence of an insulinoma, further evaluation of the case revealed inadvertent ingestion of glimepiride, a sulfonylurea not included in the standard serum sulfonylurea screen.
-
Diabetes Technol. Ther. · Jan 2003
Unrecognized hypo- and hyperglycemia in well-controlled patients with type 2 diabetes mellitus: the results of continuous glucose monitoring.
The aim of this study was to determine the prevalence and extent of glycemic excursions (hypo- and hyperglycemic) in elderly patients with well-controlled type 2 diabetes using a Continuous Glucose Monitor System (CGMS) (Medtronic MiniMed). Elderly patients (>65 years old) with type 2 diabetes were recruited if their glycosylated hemoglobin (HbA1c) was <7.5% and if their oral hypoglycemic therapy included a sulfonylurea. Patients were asked to undergo two consecutive 72-h periods of continuous glucose monitoring at baseline and then again at 1 month (total 288 h). ⋯ The CGMS was generally well tolerated, but 52% of patients could not be studied for the full 12 days of monitoring. Thus hypoglycemia and excessive postprandial glycemic excursions are common in well-controlled patients with type 2 diabetes treated with a sulfonylurea with or without metformin. The CGMS is a useful research and clinical tool to assess glycemia in patients with type 2 diabetes but is not tolerated by all subjects.