Emergency medicine journal : EMJ
-
Review Meta Analysis Comparative Study
Ultrasound guidance for difficult peripheral venous access: systematic review and meta-analysis.
Establishing intravenous access is often vital in an acute hospital setting but can be difficult. Ultrasound-guided cannulation increases success rates in prospective studies. However, these studies have often lacked a comparative group. This systematic review and meta-analysis aimed to determine the clinical effectiveness of Ultrasound-guided peripheral intravenous cannulation compared with the standard technique in patients known to have difficult access. ⋯ Ultrasound guidance increases the likelihood of successful peripheral cannulation in difficult access patients. We recommend its use in patients who have difficult venous access, and have failed venous cannulation by standard methods. Further randomised controlled trials (RCTs) with larger sample sizes would be of benefit to investigate if Ultrasound has any additional advantages in terms of reducing the procedure time and the number of skin punctures required for successful venous cannulation.
-
Comparative Study
The usefulness of rapid point-of-care creatinine testing for the prevention of contrast-induced nephropathy in the emergency department.
Renal dysfunction is the most important factor to consider when predicting a patient's risk of developing contrast-induced nephropathy (CIN). Measurement of creatinine (Cr) via rapid point-of-care blood urea nitrogen/creatinine testing (POCT-BUN/Cr) to determine CIN risk could potentially reduce the time required to achieve an accurate diagnosis and to initiate and complete treatment in the emergency department (ED). The aim of our study was to compare the results of POCT-BUN/Cr and reference laboratory tests for BUN and serum Cr. ⋯ This study suggests that POCT-BUN/Cr results correlate well with those of serum reference tests in terms of BUN and Cr levels and, in turn, predicting CIN. POCT-BUN/Cr is easily performed with a rapid turnaround time, suggesting its use in the ED may have substantial clinical benefit.
-
High-sensitivity troponin assays facilitate the rapid exclusion of acute myocardial infarction (AMI). However, elevated results are also seen in other conditions causing myocardial injury. Serial measurements increase the specificity for AMI, helping to rapidly identify patients for whom revascularisation may be appropriate. In this study, we explore a strategy for rapidly excluding AMI in symptomatic patients using serial high-sensitivity troponin measurements. ⋯ (1) all patients presenting more than 3 h after symptom onset with a negative result had a second negative result; (2) AMI was excluded in all patients with two results falling below the lower limit of detection of a standard troponin assay by 8 h post-symptom onset.
-
Comparative Study
Transport with ongoing resuscitation: a comparison between manual and mechanical compression.
In special circumstances it may be necessary to transport out-of-hospital cardiac arrest patients with ongoing resuscitation to the hospital. External mechanical chest compression devices could be an alternative for these resuscitations. The study compares manual chest compression with external mechanical devices and a semiautomatic device in transport conditions using a resuscitation manikin. ⋯ During a patient transport with ongoing resuscitation, external mechanical compression devices may be a good alternative to manual compression because they increase the safety of the rescuer and patient. Yet, in this study only animax mono reached the guideline specifications regarding chest compressions' frequency and depth. Concerning constancy, the mechanical devices work reliably and more independently from motion influences. Further studies are necessary to evaluate the effectiveness of these devices in patient transport.