IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society
-
IEEE Trans Neural Syst Rehabil Eng · Sep 2003
Clinical TrialInfluence of different stimulation frequencies on power output and fatigue during FES-cycling in recently injured SCI people.
This study investigated whether power output during 30 min sessions of functional electrical stimulation (FES)-cycling can be increased by using stimulation frequencies higher than 30 Hz. The stimulation frequencies of FES-cycling training sessions of 19 recently injured para- and tetraplegics were randomly set at 30, 50, or 60 Hz and power output (PO) was measured continually. ⋯ A 19% and 25% higher mean PO was reached at 50 and 60 Hz, respectively, compared to 30 Hz. The PO of the last minute of each session was almost always higher than the mean PO of the whole session and also higher at higher frequencies, which indicates that no muscle fatigue could be detected in 30 min FES-cycling at any of the tested frequencies.
-
IEEE Trans Neural Syst Rehabil Eng · Sep 2003
Comparative StudyPrevention of muscle disuse atrophy by low-frequency electrical stimulation in rats.
When muscles lose neural drive, they atrophy rapidly. Neuromuscular electrical stimulation (NMS) has been used in attempts to prevent or reverse the atrophy, but optimal stimulation programs and parameters are not well defined. In this study, we investigated the effects of four different stimulation patterns on disuse atrophy produced in the tibialis anterior, lateral gastrocnemius, and soleus muscles of rats paralyzed with tetrodotoxin for seven days. ⋯ The level of atrophic change was not correlated with the levels of serum creatine kinase, used as an index of muscle damage. Results suggest that remediation of disuse atrophy may be accomplished using unphysiologically low rates of motor-unit activation despite the relatively low force produced by such unfused contractions. This may have significant implications for the design of therapies for muscle paralysis consequent to upper-motoneuron lesions.
-
IEEE Trans Neural Syst Rehabil Eng · Mar 2003
A miniaturized neuroprosthesis suitable for implantation into the brain.
This paper presents current research on a miniaturized neuroprosthesis suitable for implantation into the brain. The prosthesis is a heterogeneous integration of a 100-element microelectromechanical system (MEMS) electrode array, front-end complementary metal-oxide-semiconductor (CMOS) integrated circuit for neural signal preamplification, filtering, multiplexing and analog-to-digital conversion, and a second CMOS integrated circuit for wireless transmission of neural data and conditioning of wireless power. ⋯ The neuroprosthetic system design has strict size and power constraints with each of the front-end preamplifier channels fitting within the 400 x 400-microm pitch of the 100-element MEMS electrode array and power dissipation resulting in less than a 1 degree C temperature rise for the surrounding brain tissue. We describe the measured performance of initial micropower low-noise CMOS preamplifiers for the neuroprosthetic.
-
IEEE Trans Neural Syst Rehabil Eng · Dec 2002
Comparative StudyFunctionally selective peripheral nerve stimulation with a flat interface nerve electrode.
One of the important goals of peripheral nerve electrode development is to design an electrode for selective recruitment of the different functions of a common nerve trunk. A challenging task is gaining selective access to central axon populations. In this paper, a simple electrode that takes advantage of the neural plasticity to reshape the nerve is presented. ⋯ The stimulation thresholds were 2.89 nC for pulse amplitude modulation and 10.2 nC for pulse-width modulation. Monopolar, square-pulse stimulation with single contacts on the FINE selectively recruited each of the four main branches of the sciatic nerve. Simultaneous stimulation with two contacts produced moments about the ankle joint that were a combination of the moments produced by the individual contacts when stimulated separately.
-
IEEE Trans Neural Syst Rehabil Eng · Sep 2002
Comparative Study Clinical TrialDevelopment of an indoor rowing machine with manual FES controller for total body exercise in paraplegia.
Concept 2 indoor rowing machine (Concept 2 Inc., USA) was modified for functional electrical stimulation (FES) rowing exercise in paraplegia. A new seating system provides trunk stability and constrains the leg motion to the sagittal plane. A 4-channel electrical stimulator activates the quadriceps and hamstrings in Drive and Recovery phases of the rowing cycle, respectively. ⋯ It uses the voluntary thumb presses to control the timing of the stimulation to the paralyzed leg muscles. The manual control system was intuitive and easy to learn and resulted in well-coordinated rowing. Evaluation of the modified rower by paraplegic volunteers showed that it is effective, safe, and affordable exercise alternative for paraplegics.