A pilot study of myoelectrically controlled FES of upper extremity.
Functional electrical stimulation (FES) of upper limbs can be used for the recovery of some hand functions on patients with CNS lesions. This study deals with the control of FES by means of myoelectrical activity detected from voluntarily activated paretic muscles. The specific aim of this paper is to evaluate the accuracy of myoelectrical control in terms of produced force and movement. ⋯ The hemiplegic patient showed limited thumb control with the MeCFES but indicated the possibility of a carry over effect. It was found that a low residual natural force resulted in a less accurate movement but also with a large increase (up to ten times) of the muscle output. On the contrary, persons with a medium residual force obtained a smaller amplification of muscle force with a higher tracking accuracy.
-
IEEE Trans Neural Syst Rehabil Eng · Mar 2001
Rapid prototyping of an EEG-based brain-computer interface (BCI).
The electroencephalogram (EEG) is modified by motor imagery and can be used by patients with severe motor impairments (e.g., late stage of amyotrophic lateral sclerosis) to communicate with their environment. Such a direct connection between the brain and the computer is known as an EEG-based brain-computer interface (BCI). This paper describes a new type of BCI system that uses rapid prototyping to enable a fast transition of various types of parameter estimation and classification algorithms to real-time implementation and testing. ⋯ The BCI can be controlled over the Internet, LAN or modem. This BCI was tested on 3 subjects whose task it was to imagine either left or right hand movement. A classification accuracy between 70% and 95% could be achieved with two EEG channels after some sessions with feedback using an adaptive autoregressive (AAR) model and linear discriminant analysis (LDA).
-
IEEE Trans Neural Syst Rehabil Eng · Mar 2001
Electrodeposited iridium oxide for neural stimulation and recording electrodes.
Iridium oxide films formed by electrodeposition onto noniridium metal substrates are compared with activated iridium oxide films (AIROFs) as a low impedance, high charge capacity coating for neural stimulation and recording electrodes. The electrodeposited iridium oxide films (EIROFs) were deposited on Au, Pt, PtIr, and 316 LVM stainless steel substrates from a solution of IrCl4, oxalic acid, and K2CO3. A deposition protocol involving 50 potential sweeps at 50 mV/s between limits of 0.0 V and 0.55 V (versus Ag AgCl) followed by potential pulsing between the same limits produced adherent films with a charge storage capacity of >25 mC/cm2. ⋯ Stability under charge injection was evaluated using 200 micros, 5.9 A/cm2 (1.2 mC/cm2) cathodal pulses. Loss of iridium oxide charge capacity was comparable for AIROFs and the EIROFs, ranging from 1% to 8% of the capacity immediately after activation or deposition. The EIROFs were deposited and evaluated on silicon microprobe electrodes and on metallized polyimide electrodes being developed for neural recording and stimulation applications.