The spine journal : official journal of the North American Spine Society
-
The anatomy of the atlantoaxial joint makes stabilization at this level challenging. Current techniques that use transarticular screw fixation (Magerl) or segmental screw fixation (Harms) give dramatically improved stability but risk damage to the vertebral artery. A novel integrated device was designed and developed to obtain intra-articular stabilization via primary interference fixation within the C1-C2 lateral mass articulation. ⋯ The integrated device resulted in interference fixation at the C1-C2 lateral mass joints with comparable stability to the Harms technique. Perceived advantages with the integrated device include avoidance of fixation below the C2 lateral mass where the vertebral artery is susceptible to injury, and access to the C1 screw entry point through the blade of the integrated device avoiding extended dissection superior to the C2 nerve root and its surrounding venous plexus.
-
Repeat lumbar spine surgery is generally an undesirable outcome. Variation in repeat surgery rates may be because of patient characteristics, disease severity, or hospital- and surgeon-related factors. However, little is known about population-level variation in reoperation rates. ⋯ Even after adjusting for patient demographics and comorbidity, we observed a large variation in reoperation rates across hospitals and surgeons after lumbar discectomy, a relatively simple spinal procedure. These findings suggest uncertainty about indications for repeat surgery, variations in perioperative care, or variations in quality of care.
-
Anterior cervical plating increases stability and hence improves fusion rates to treat cervical spine pathologies, which are often symptomatic at multiple levels. However, plating is not without complications, such as dysphagia, injury to neural elements, and plate breakage. The biomechanics of a spacer with integrated plate system combined with posterior instrumentation (PI), in two-level and three-level surgical models, has not yet been investigated. ⋯ The anatomically profiled spacer with integrated plate allows treatment of cervical disorders with fewer steps and less impact to cervical structures. In this biomechanical study, spacer with integrated plate construct showed comparable stability to traditional spacer and plate for two-level and three-level fusion. Posterior instrumentation showed significant effect only in three-level fusion. Clinical data are required for further validation of using spacer with integrated plate at multiple levels.
-
The intervertebral disc plays a major functional role in the spinal column, providing jointed flexibility and force transmission. The end plate acts as an important structural transition between the hard vertebral tissues and the compliant disc tissues and is therefore a region of potentially high stress concentration. The effectiveness of anchorage of the tough annulus fibers in the end plate will have a major influence on the overall strength of the motion segment. Failure of the end plate region is known to be associated with disc herniation. ⋯ Given both the limited thickness of the end plate and the intrinsic strength of the interface bond between bundle and end plate matrix, the branched morphology is consistent with a mechanism of optimal shear stress transfer wherein a greater strength of annular fiber anchorage can be achieved over a relatively short insertion distance.
-
Present studies concerning the safety and reliability of neurophysiological monitoring during thoracic pedicle screw placement remain inconclusive, and therefore, universally validated threshold levels that confirm osseous breakage of the instrumented pedicles have not been properly established. ⋯ In the experimental animals, the observed electrical impedance depended on the distance of screws from the neural structures and not on the integrity of the pedicle cortex. The screw-triggered EMG technique did not reliably discriminate the presence or absence of bone integrity after pedicle screw placement. The response intensity was not related to the type of interposed tissue.