• Catheter Cardiovasc Interv · Jan 2014

    Pediatric patient radiation dosage during endomyocardial biopsies and right heart catheterization using a standard "ALARA" radiation reduction protocol in the modern fluoroscopic era.

    • Nicole J Sutton, Jacqueline Lamour, Laura A Gellis, and Robert H Pass.
    • Division of Cardiology, Department of Pediatrics, Pediatric Cardiac Catheterization Laboratory, Children's Hospital at Montefiore Albert Einstein College of Medicine, Yeshiva University, Bronx, New York.
    • Catheter Cardiovasc Interv. 2014 Jan 1; 83 (1): 80-3.

    BackgroundSurveillance endomyocardial biopsy (EMB) with right heart catheterization (RHC) is the standard of care for the assessment of post cardiac transplantation rejection. This procedure has traditionally relied upon fluoroscopy, which exposes both patient and staff to the risks of ionizing radiation. These risks may be of particular concern in the transplant patient who must undergo many such procedures lifelong. We present data on a new "ALARA - As Low As Reasonably Achievable" protocol to reduce radiation exposure during the performance of RHC with EMB.MethodsAll cardiac transplantation patients < 21 years of age who underwent RHC with EMB at The Children's Hospital at Montefiore from 6/11-12/11 were included. EMB was performed after all right heart pressures including wedge pressure and thermodilution cardiac output were measured. A novel ALARA protocol consisting of multiple features including ultra-low frame rates (2-3 fps), low fluoro dose/frame (10-18 nGy/frame), use of the "air-gap" technique for patients < 20 kg, and multiple other techniques aimed at minimizing use of fluoroscopy were employed in all cases. Demographics, procedural data and patient radiation exposure levels were collected and analyzed.Results18 patients underwent 45 surveillance RHC with EMB in the study period and were the subject of this analysis. The mean age was 5.9 ± 6.1 years, weight was 20.4 kg ± 16.6 kg, and BSA was 0.75 ± 45 m(2) . PA fluoroscopy was used exclusively in 45/45. Vascular access was RFV (21/45; 47%), RIJV (17/45; 38%), LFV (4/45; 9%) and LIJV (3/45; 7%). The median number of EMB specimens obtained was 5 (range, 4-7). The median fluoroscopy time was 3.7 min (range, 1.2-9). The median air Kerma product (K) was 1.4 mGy (range, 0.4-14), and dose area product (DAP) was 15.8 uGym(2) (range, 3.5-144.5). The K and DAP are substantially lower than any prior published data for RHC/EMB in this patient group. There were no procedural complications.ConclusionsThe use of a novel ALARA protocol for RHC and EMB in pediatric cardiac transplantation patients markedly reduced radiation exposure to levels far below any previously reported values without negatively affecting the safety or efficacy of these procedures.Copyright © 2013 Wiley Periodicals, Inc.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…