Case Reports
Use of a Non-invasive Cardiac Output Measurement in a Patient with Low-output Dilated Cardiomyopathy.
- Atsuko Nakayama, Kentaro Iwama, Naohiro Makise, Yukako Domoto, Junichi Ishida, Hiroyuki Morita, and Issei Komuro.
- Department of Cardiovascular Medicine, The University of Tokyo Hospital, Japan.
- Intern. Med. 2020 Jun 15; 59 (12): 1525-1530.
AbstractA 49-year-old man was diagnosed with acute cardiac insufficiency based on evidence of congestive heart failure. The non-invasive measurement of the cardiac output using an AESCULON® mini showed low cardiac output (CO, 3.9 L/min). We administered an intravenous diuretic for cardiac edema and dobutamine drip for low cardiac output. Soon after starting dobutamine at 3.2 γ (microg/kg/min), the CO improved to 6.8 L/min. Combination therapy of diuretic and dobutamine resolved the heart failure. CO measurement by an AESCULON® mini was safe, cost-effective, and convenient. Data output correlates with the CO by Swan-Ganz catheterization. The non-invasive measurement of the CO permitted a smooth recovery without recurrence in this patient.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*,_underline_or**bold**. - Superscript can be denoted by
<sup>text</sup>and subscript<sub>text</sub>. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3., hyphens-or asterisks*. - Links can be included with:
[my link to pubmed](http://pubmed.com) - Images can be included with:
 - For footnotes use
[^1](This is a footnote.)inline. - Or use an inline reference
[^1]to refer to a longer footnote elseweher in the document[^1]: This is a long footnote..