J. Cardiothorac. Vasc. Anesth. · Apr 2011
Randomized Controlled Trial Comparative StudyHemodynamic stability during biventricular pacing after cardiopulmonary bypass.
- Mathew E Spotnitz, Daniel Y Wang, T Alexander Quinn, Marc E Richmond, Alexander Rusanov, Taylor Johnston, Bin Cheng, Santos E Cabreriza, and Henry M Spotnitz.
- Department of Surgery, Columbia University Medical Center, New York, NY 10032-3784, USA. hms2@columbia.edu
- J. Cardiothorac. Vasc. Anesth. 2011 Apr 1; 25 (2): 238242238-42.
ObjectiveTo assess the stability of cardiac output, mean arterial pressure, and systemic vascular resistance during biventricular pacing (BiVP) optimization.DesignSubstudy analysis of data collected as part of a randomized controlled study examining the effects of optimized temporary BiVP after cardiopulmonary bypass (CPB).SettingA single-center study at a university-affiliated tertiary care hospital.ParticipantsCardiac surgery patients at risk of left ventricular failure after CPB.InterventionsBiVP was optimized immediately after CPB. Atrioventricular delay (7 unique settings) was optimized first, followed by the left ventricular pacing site (3 unique settings) and then the interventricular delay (9 unique settings). Each setting was tested twice for 10 seconds each time. Vasoactive medication and fluid infusion rates were held constant.Measurements And Main ResultsAortic flow velocity and radial artery pressure were digitized, recorded, and averaged over single respiratory cycles. Least squares and linear regression/Wilcoxon analyses were applied to the first 7 patients studied. Subsequently, curvilinear analysis was applied to 15 patients. Changes in mean arterial pressure and systemic vascular resistance were statistically insignificant or too small to be meaningful by least squares analysis. During interventricular synchrony optimization, cardiac output and mean arterial pressure decreased (mean changes -5.7% and -2.5%, respectively; with standard errors 2.3% and 1.5%, respectively), whereas SVR increased (mean change 3.1% with standard error 3.4%). Only the change in cardiac output was statistically significant (p = 0.043). Curvilinear fits to data for 15 patients demonstrated progressive hemodynamic stability over the total testing period.ConclusionBiVP optimization may be done safely in patients after CPB. With continuous monitoring of mean arterial pressure and cardiac output, the procedure results in no harmful hemodynamic perturbation.Copyright © 2011 Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.