Observational Study
The usefulness of non-invasive co-oximetry haemoglobin measurement for screening pre-operative anaemia.
- Y H Ke, K Y Hwang, T N Thin, Y E Sim, and H R Abdullah.
- Division of Anaesthesiology and Peri-operative Medicine, Singapore General Hospital, Singapore.
- Anaesthesia. 2021 Jan 1; 76 (1): 54-60.
AbstractPre-operative anaemia (haemoglobin < 13.0 g.dl-1 ) is a modifiable peri-operative risk-factor. This is screened for using formal laboratory testing. A non-invasive finger-probe sensor that can accurately measure haemoglobin is a possible alternative. This study considers the accuracy of non-invasive haemoglobin measurement using the Rad-67™ Rainbow (Masimo Corp., Irvine, CA, USA) compared with formal laboratory testing and its usefulness in detecting pre-operative anaemia. A total of 392 patients had measurements taken for non-invasive haemoglobin and perfusion index values using the Rad-67 Rainbow, alongside further peri-operative parameters and a formal laboratory haemoglobin test. Bland-Altman and sensitivity analysis showed that the limits of agreement between non-invasive and formal laboratory haemoglobin testing were between -1.95 g.dl-1 and 2.23 g.dl-1 (p < 0.001). The overall performance of non-invasive haemoglobin measurement was better in men than women (ROC 91.1% vs. 78.2%) and less biased in men, mean -0.08 (SD 1.09, 95%Cl -0.23-0.07) compared with women (mean 0.38 (SD 0.99, 95%CI 0.24-0.52)). Pre-operative anaemia was more prevalent in women than men (50.3% vs. 14.4%). The sensitivity of non-invasive anaemia detection (haemoglobin < 13 g.dl-1 ) was 66% for women and 52% for men. A non-invasive haemoglobin value of 14.0 g.dl-1 had an overall 91% sensitivity for detecting pre-operative anaemia (82% in men and 93% in women). The Rad-67 Rainbow is inadequate for the estimation of formal laboratory haemoglobin and lacks sensitivity for detecting pre-operative anaemia, especially in women. Further advancement in technology and accuracy is needed before it can be recommended as a routine pre-operative screening test.© 2020 Association of Anaesthetists.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.