    RationaleThe use of extra-positive end-expiratory pressure (PEEP) at a level of 80% intrinsic-PEEP (iPEEP) to improve ventilation in severe asthma patients with control ventilation remains controversial. Electrical impedance tomography (EIT) may provide regional information for determining the optimal extra-PEEP to overcome gas trapping and distribution. Moreover, the experience of using EIT to determine extra-PEEP in severe asthma patients with controlled ventilation is limited.Patients ConcernsA severe asthma patient had 12-cmH2O iPEEP using the end-expiratory airway occlusion method at Zero positive end-expiratory pressures (ZEEP). How to titrate the extra-PEEP to against iPEEP at bedside?Diagnoses And InterventionsAn incremental PEEP titration was performed in the severe asthma patient with mechanical ventilation. An occult pendelluft phenomenon of the ventral and dorsal regions was found during the early and late expiration periods when the extra-PEEP was set to <6 cmH2O. If the extra-PEEP was elevated from 4 to 6 cmH2O, a decrease in the end-expiratory lung impedance (EELI) and a disappearance of the pendelluft phenomenon were observed during the PEEP titration. Moreover, there was broad disagreement as to the "best" extra-PEEP settings according to the various EIT parameters. The regional ventilation delay had the lowest extra-PEEP value (10 cmH2O), whereas the value was 12 cmH2O for the lung collapse/overdistension index and 14 cmH2O for global inhomogeneity.OutcomesThe extra-PEEP was set at 6 cmH2O, and the severe whistling sound was improved. The patient's condition further became better under the integrated therapy.LessonsA broad literature review shows that this was the 3rd case of using EIT to titrate an extra-PEEP to against PEEPi. Importantly, the visualization of occult pendelluft and possible air release during incremental PEEP titration was documented for the first time during incremental PEEP titration in patients with severe asthma. Examining the presence of the occult pendelluft phenomenon and changes in the EELI by EIT might be an alternative means for determining an individual's extra-PEEP.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…