Comparative StudyComparative feasibility of myocardial velocity and strain measurements using 2 different methods with transesophageal echocardiography during cardiac surgery.
- Graeme MacLaren, Roman Kluger, Kim A Connelly, and Colin F Royse.
- Department of Anaesthesia, St Vincent's Hospital, Melbourne, Australia. gmaclaren@iinet.net.au
- J. Cardiothorac. Vasc. Anesth.. 2011 Apr 1;25(2):216-20.
ObjectiveTo assess the feasibility and correlation between tissue Doppler and speckle tracking imaging when measuring myocardial velocity, strain, and strain rate with transesophageal echocardiography.DesignA prospective, observational study.SettingAn academic tertiary-referral hospital.ParticipantsPatients undergoing elective heart surgery.InterventionsNone.Measurements And Main ResultsVelocity, strain, and strain rate were measured using both techniques in the inferior and anterior walls in transgastric views for radial motion and in the lateral, septal, anterior, and inferior walls in midesophageal views for longitudinal motion. Nineteen patients and 304 myocardial segments were studied. Overall, tissue Doppler was found to be more successful than speckle tracking in measuring myocardial velocity, whereas strain and strain rate measurements were achieved with comparable success using either method. Tissue Doppler was more successful than speckle tracking for radial cardiac motion, and the highest success rates were achieved with this method (93.4% v 59.2% for velocity, p < 0.001; 78.9% v 59.2% for strain, p = 0.01; and 73.7% v 59.2% for strain rate, p = 0.09). Good correlation between tissue Doppler and speckle tracking was shown in 4 myocardial segments: radial midinferior, radial basal inferior, radial basal anterior, and longitudinal basal septum (R = 0.6-0.82, p < 0.05).ConclusionsThe correlation between tissue Doppler and speckle tracking with transesophageal echocardiography appears valid when predominantly confined to segments moving in a radial direction adjacent to the ultrasound transducer. Tissue Doppler echocardiography of radial cardiac motion appears to be the most feasible technique of measuring myocardial velocity, strain, and strain rate during cardiac surgery.Copyright © 2011 Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.