• Neuromodulation · Oct 2004

    The sensitivity and selectivity of an implantable two-channel peroneal nerve stimulator system for restoration of dropped foot.

    • Anke I R Kottink, Hendrik P J Buschman, Laurence P J Kenney, Peter H Veltink, Per Slycke, Gerrit Bultstra, and Hermie J Hermens.
    • Roessingh Research & Development bv, Twente Institute for Neuromodulation, Medisch Spectrum Twente, Enschede, the Netherlands; Center for Rehabilitation and Human Performance Research, University of Salford, Salford, United Kingdom; Institute for Biomedical Technology (BMTI), University Twente, Xsens Sports Technology B.V., Department of Biomedical Engineering, University of Twente, Enschede, the Netherlands.
    • Neuromodulation. 2004 Oct 1;7(4):277-83.

    AbstractThe objective of this study was to evaluate the stimulation responses on each channel of an implantable two-channel stimulator that stimulates the peroneal nerve branches innervating the muscles for dorsiflexion and eversion movements. Currently five Dutch patients and five English patients have been implanted with this system. Isometric ankle torque measurements were carried out in the patient with the longest follow-up period (1 y). A force sensor measured the three components of moment generated at the ankle joint. Stimulation intensity can be adjusted with great accuracy. Dorsiflexion moments are almost entirely determined by the setting of channel 1. Eversion moments are determined mainly by channel 2 and to a lesser extent by channel 1. Both channels determined abduction/adduction moments. We conclude that stimulation responses in both dorsiflexion and eversion direction can be set individually and with great accuracy and are reproducible over a prolonged period.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…