Randomized Controlled Trial Comparative Study Clinical Trial
Supraglottic airway device versus a channeled or non-channeled blade-type videolaryngoscope for accidental extubation in the prone position: A randomized crossover manikin study.
- Hiroyuki Oshika, Yukihide Koyama, Masataka Taguri, Koichi Maruyama, Go Hirabayashi, Shoko Merrit Yamada, Masashi Kohno, and Tomio Andoh.
- Department of Anesthesiology, Mizonokuchi Hospital, Teikyo University School of Medicine, Kawasaki.
- Medicine (Baltimore). 2018 Jun 1; 97 (25): e11190.
BackgroundIt is very rare but challenging to perform emergency airway management for accidental extubation in a patient whose head and neck are fixed in the prone position when urgently turning the patient to the supine position would be unsafe. The authors hypothesized that tracheal intubation with a videolaryngoscope would allow effective airway rescue in this situation compared with a supraglottic airway device and designed a randomized crossover manikin study to test this hypothesis.MethodsThe authors compared airway rescue performances of the 3 devices-the ProSeal laryngeal mask airway (PLMA; Teleflex Medical, Westmeath, Ireland) as a reference; the Pentax AWS (AWS; Nihon Kohden, Tokyo, Japan) as a channeled blade-type videolaryngoscope; and the McGRATH videolaryngoscope (McGRATH; Medtronic, Minneapolis, MN) as a nonchanneled blade type in a manikin fixed to the operating table in the prone position. Twenty-one anesthesiologists performed airway management on the prone manikin with the 3 devices, and the time required for intubation/ventilation and the success rates were recorded.ResultsThe median (range) intubation/ventilation times with the PLMA, AWS, and McGRATH were 24.5 (13.5-89.5) s, 29.9 (17.1-79.8) s, and 46.7 (21.9-211.7) s, respectively. There was no significant difference in intubation/ventilation times between the PLMA and AWS. The AWS permitted significantly faster tracheal intubation than did the McGRATH (P = 0.006). The success rates with the PLMA (100%) and AWS (100%) were significantly greater than that with the McGRATH (71.4%). Airway management performance of the PLMA and AWS was comparable between devices and better than that of the McGRATH in the prone position.ConclusionsConsidering that tracheal intubation can provide a more secure airway and more stable ventilation than the PLMA, re-intubation with a channeled blade-type videolaryngoscope such as the AWS may be a useful method of airway rescue for accidental extubation in patients in the prone position.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.