-
Eur. J. Heart Fail. · Apr 2018
Multicenter StudyResting and exercise haemodynamics in relation to six-minute walk test in patients with heart failure and preserved ejection fraction.
- Emil Wolsk, David Kaye, Barry A Borlaug, Daniel Burkhoff, Dalane W Kitzman, Jan Komtebedde, Lam Carolyn S P CSP National Heart Centre Singapore, Singapore and Duke-National University of Singapore, Singapore., Piotr Ponikowski, Sanjiv J Shah, and Finn Gustafsson.
- Department of Cardiology, Rigshospitalet, Copenhagen, Denmark.
- Eur. J. Heart Fail. 2018 Apr 1; 20 (4): 715-722.
AimsPatients with heart failure and preserved ejection fraction (HFpEF) are characterized by functional impairment and an abnormal haemodynamic response to exercise. The six-minute walk test (6MWT) serves as a standardized test for functional capacity quantification in heart failure patients, and is associated with cardiovascular outcomes. However, as the association between 6MWT and haemodynamic parameters during rest and exercise in HFpEF patients is unknown, we sought to elucidate this relationship.Methods And ResultsOverall, 64 patients enrolled in the REDUCE LAP-HF trial completed a 6MWT at baseline. Univariate and multivariable linear regression models were used to assess the associations between 6MWT and measured or derived haemodynamic variables at baseline, during light/moderate exercise (20 W), and at peak supine exercise. The average 6MWT distance was 318 ± 106 m. At rest, in a multivariable model, only pulmonary capillary wedge pressure (PCWP) was significantly associated with 6MWT [coefficient: -5.4, 95% confidence interval (CI) -10.4, -0.5, P = 0.033]. During light/moderate exercise, mean pulmonary artery pressure was associated with 6MWT in a multivariable model (coefficient: -3.5, 95% CI -6.8, -0.3, P = 0.033). During peak exercise, central venous pressure, cardiac index (CI), and PCWP/CI correlated with 6MWT; however, workload corrected PCWP was the only variable independently associated with 6MWT (coefficient: -0.8, 95% CI -1.3, -0.4, P < 0.001). The variance in 6MWT was modestly explained by measured or derived haemodynamic variables at rest or at any stage of exercise (r2 = 7-17%).ConclusionWorkload corrected PCWP correlated best with 6MWT performance in HFpEF patients. Baseline haemodynamic variables were modestly correlated with 6MWT, suggesting that 6MWT performance in HFpEF patients may be significantly influenced by extra-cardiac factors.© 2017 The Authors. European Journal of Heart Failure © 2017 European Society of Cardiology.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.