- Michael Stanchina, Kristen Robinson, William Corrao, Walter Donat, Scott Sands, and Atul Malhotra.
- 1 Pulmonary, Critical Care, and Sleep Medicine, Alpert Medical School at Brown University, Providence, Rhode Island.
- Ann Am Thorac Soc. 2015 Sep 1; 12 (9): 1351-7.
RationaleMeasures of unstable ventilatory control (loop gain) can be obtained directly from the periodic breathing duty ratio on polysomnography in patients with Cheyne-Stokes respiration/central sleep apnea and can predict the efficacy of continuous positive airway pressure (CPAP) therapy.ObjectivesIn this pilot study, we aimed to determine if this measure could also be applied to patients with complex sleep apnea (predominant obstructive sleep apnea, with worsening or emergent central apneas on CPAP). We hypothesized that loop gain was higher in patients whose central events persisted 1 month later despite CPAP treatment versus those whose events resolved over time.MethodsWe calculated the duty ratio of the periodic central apneas remaining on the CPAP titration (or second half of the split night) while patients were on optimal CPAP with the airway open (obstructive apnea index < 1/h). Loop gain was calculated by the formula: LG = 2π/[(2πDR - sin(2πDR)]. Patients were followed on CPAP for 1 month. Post-treatment apnea-hypopnea index and compliance data were recorded from smart cards.Measurements And Main ResultsThirty-two patients with complex sleep apnea were identified, and 17 patients had full data sets. Eight patients continued to have a total of more than five events per hour (11.8 ± 0.5/h) (nonresponders). The remaining nine patients had an apnea-hypopnea index less than 5/h (2.2 ± 0.4/h) (responders). Loop gain was higher in the nonresponders versus responders (2.0 ± 0.1 vs. 1.7 ± 0.2, P = 0.026). Loop gain and the residual apnea-hypopnea index 1 month after CPAP were associated (r = 0.48, P = 0.02). CPAP compliance was similar between groups.ConclusionsIn this pilot study, loop gain was higher for patients with complex sleep apnea in whom central apneas persisted after 1 month of CPAP therapy (nonresponders). Loop gain measurement may enable an a priori determination of those who need alternative modes of positive airway pressure.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.