J. Cardiothorac. Vasc. Anesth. · Apr 2011
Randomized Controlled Trial Comparative StudyDirect observation of the human microcirculation during cardiopulmonary bypass: effects of pulsatile perfusion.
- Paul W G Elbers, Jeroen Wijbenga, Frank Solinger, Aladdin Yilmaz, Mat van Iterson, Eric P A van Dongen, and Can Ince.
- Department of Physiology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands. info@acidbase.org
- J. Cardiothorac. Vasc. Anesth.. 2011 Apr 1;25(2):250-5.
ObjectivesPossible benefits of pulsatile perfusion during cardiopulmonary bypass often are attributed to enhanced microvascular flow. However, there is no evidence to support this in humans. Therefore, the authors assessed whether pulsatile perfusion alters human microvascular flow.DesignA prospective, randomized observational crossover study.SettingA tertiary cardiothoracic surgery referral center.ParticipantsSixteen patients undergoing routine cardiopulmonary bypass for cardiac surgery.InterventionsAll patients underwent both pulsatile and nonpulsatile perfusion in random order.Measurements And Main ResultsThe authors used sidestream dark-field imaging to record video clips of the sublingual human microcirculation. Perfusion was started either in the pulsatile (n = 8) or the nonpulsatile mode. After 10 minutes, microvascular recordings were made. The perfusion mode was then switched, and after 10 minutes, new microvascular recordings were taken. The authors quantified pulsatile perfusion-generated surplus hemodynamic energy by calculating pulse pressure and energy-equivalent pressure. Microvascular analysis included determination of the perfused vessel density (mean ± standard deviation). This did not differ between nonpulsatile and pulsatile perfusion (6.65 ± 1.39 v 6.83 ± 1.23 mm(-1), p = 0.58, and 2.16 ± 0.64 v 1.96 ± 0.48 mm(-1), p = 0.20 for small and large microvessels, respectively, cutoff diameter = 20 μm). Pulse pressure and energy-equivalent pressure was higher during pulsatile perfusion. However, there was no correlation between the difference in energy-equivalent pressure or pulse pressure and perfused vessel density (r = -0.43, p = 0.13, and r = -0.09, p = 0.76, respectively).ConclusionPulsatile perfusion does not alter human microvascular perfusion using standard equipment in routine cardiac surgery. Changes in pulse pressure or energy-equivalent pressure bear no obvious relationship with microcirculatory parameters.Copyright © 2011 Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.